Difference between revisions of "CNC Bender v14.9-r10"

From ATTWiki
Jump to: navigation, search
(25px ENHANCEMENT: SUPRAVISION Communications)
(25px ENHANCEMENT: Benderlink Change for ROMER Software)
 
(10 intermediate revisions by one user not shown)
Line 16: Line 16:
 
__NOTOC__
 
__NOTOC__
  
==[[image:Check.jpg|25px]] ENHANCEMENT: Cross Slide Check  ==
+
==[[image:Check.jpg|25px]] ENHANCEMENT: Benderlink Change for ROMER Software Communications ==
 +
 
 
<table>
 
<table>
 
<tr>
 
<tr>
 
<td width=500>
 
<td width=500>
In previous versions of CNC Bender, the internal logic would not allow the manual page jog close of either PRESSURE die or CLAMP die if the Cross Slide INPUT for AWAY from die (or in the home position) was active.<br><br>
+
 
This has been changed so that CNC Bender now only examines the Cross Slide INPUT for ADVANCED or IN the die active.<br><br>
+
Previous versions of CNC Bender Benderlink would send Supravision data with XYZ values even if the XYZ values had not been setup (and were all zeros).<br><br>
'''This allows for locking the carriage cross slide for little or no movement - with both prox switched active at the same time - and still close the dies.'''
+
This caused ROMER software products to refuse the incoming data and display an error.<br><br>
 +
'''This release of CNC Bender will automatically remove the XYZ data if they are all zeros.  This satisfies the ROMER software rules.'''
 +
</td>
 +
<td>
 +
[[image:romer_infinite.jpg]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 28: Line 33:
 
<br><br>
 
<br><br>
  
==[[image:Check.jpg|25px]] ENHANCEMENT: SUPRAVISION Communication Change for ROMER Software ==
+
==[[image:Check.jpg|25px]] ENHANCEMENT: Cross Slide Check  ==
 
+
 
<table>
 
<table>
 
<tr>
 
<tr>
 
<td width=500>
 
<td width=500>
 
+
In previous versions of CNC Bender, the internal logic would not allow the manual jog close of either PRESSURE die or CLAMP die if the Cross Slide input prox for AWAY from die (or in the home position) was active.<br><br>
Previous versions of CNC Bender would send Supravision data with XYZ values even if the XYZ values had not been setup (and were all zeros).<br><br>
+
This has been changed so that CNC Bender now only examines the Cross Slide input prox for ADVANCED or IN the die active.<br><br>
This caused ROMER software products to refuse the incoming data and display an error.<br><br>
+
'''This allows for locking the carriage cross slide for little or no movement - with both HOME and ADVANCED proximity switches active at the same time - and still close the dies.'''
'''This release of CNC Bender will automatically remove the XYZ data if they are all zeros.  This satisfies the ROMER software rules.'''
+
</td>
 +
<td>
 +
[[image:cncbender_crossslide.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 14:36, 12 March 2016

v14.9-r10 - March 10, 2015

Cncbender v14 logo.png


Check.jpg ENHANCEMENT: Benderlink Change for ROMER Software Communications

Previous versions of CNC Bender Benderlink would send Supravision data with XYZ values even if the XYZ values had not been setup (and were all zeros).

This caused ROMER software products to refuse the incoming data and display an error.

This release of CNC Bender will automatically remove the XYZ data if they are all zeros. This satisfies the ROMER software rules.

Romer infinite.jpg



Check.jpg ENHANCEMENT: Cross Slide Check

In previous versions of CNC Bender, the internal logic would not allow the manual jog close of either PRESSURE die or CLAMP die if the Cross Slide input prox for AWAY from die (or in the home position) was active.

This has been changed so that CNC Bender now only examines the Cross Slide input prox for ADVANCED or IN the die active.

This allows for locking the carriage cross slide for little or no movement - with both HOME and ADVANCED proximity switches active at the same time - and still close the dies.

Cncbender crossslide.png



Other Pages