Revision as of 16:02, 28 June 2014
Revision 1.91
|
- See VTube-LASER Customer Support Page to download the latest version.
NEW: Use Leapfrog To Measure Tubes Longer Than the Arm's Reach
NEW: Redesign for XYZ INTERSECTION Inspection Values
The data shown on the right is from the new Expanded Grid (see "Expanded Grid" section below). |
NEW: Redesign for XYZ TANGENT Inspection Values
The data shown on the right is from the new Expanded Grid (see "Expanded Grid" section below). |
NEW: Expanded Grid Window for Inspection Data, Send to MS Office
|
The XYZ Intersection deviation and the XYZ Tangent point deviation values can now be displayed in the Expanded Grid window.
|
NEW: XYZ Intersection +/- Tolerance Values in Printed Reports
|
The new XYZ Intersection deviation values are included in reports:
|
ENHANCED and NEW: Alignment Feature Changes
FEATURE 1 - ALIGNMENT ENGINE: Fixes and Significantly More Powerful
|
The automatic end weighting Best Fit alignment method is significantly improved:
|
FEATURE 2 - MEASURE COMPLETE WINDOW: Measurement Complete Dialog REDESIGNED with Alignment Choices
|
This new measurement complete dialog gives you more choices than before. It no longer assumes that you want to use the current default alignment method. |
FEATURE 2 - INSPECTION DATA MENU: Alignment Button Displays Alignment Method Selected
|
The Inspection Data recalculate alignment button now displays the currently selected alignment method. This fixes a problem where users had to guess the alignment method when recalculating the measured to master alignment. |
FEATURE 4 - ALIGNMENT MENU: Value RENAMED for Clarity
|
The Automatic Alignment Stop value in the Inspection Data / Alignment menu is renamed to make it more understandable: "Automatic Alignment Stop at Deviation Multiplied Against..." is the new name. |
NEW: Direct Communications with Eaton Leonard Premier, EL2000, and Ve-log Benders
|
Enhanced: Project Batch Report Output
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor