Difference between revisions of "Revision: Benderlink for Chiyoda/Keins 6.7"
(→25px ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter) |
(→25px ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter) |
||
| (12 intermediate revisions by one user not shown) | |||
| Line 17: | Line 17: | ||
==[[image:Check.jpg|25px]] ENHANCED - New Serial Port COM Engine Available == | ==[[image:Check.jpg|25px]] ENHANCED - New Serial Port COM Engine Available == | ||
| + | |||
| + | <table> | ||
| + | <tr valign=top> | ||
| + | <td width=400> | ||
This Benderlink can use either the new WinSoft COM engine for faster communications, or the older MarshallSoft COM engine for cases where the older engine works better.<br><br> | This Benderlink can use either the new WinSoft COM engine for faster communications, or the older MarshallSoft COM engine for cases where the older engine works better.<br><br> | ||
| − | The Benderlink.ini file is found in the c:\Users\[username]\AppData\Roaming\BenderlinkChiyodaKeins folder.<br><br>Edit the Benderlink.ini in a notepad editor. The section to change is Communications Setup "COM Engine". These are the two available setups:<br><br> | + | The Benderlink.ini file is found in the <b>c:\Users\[username]\AppData\Roaming\BenderlinkChiyodaKeins</b> folder.<br><br>Edit the Benderlink.ini in a notepad editor. The section to change is Communications Setup "COM Engine". These are the two available setups:<br><br> |
<pre> | <pre> | ||
[Communications Setup] | [Communications Setup] | ||
| Line 30: | Line 34: | ||
COM Engine=Marshallsoft | COM Engine=Marshallsoft | ||
</pre> | </pre> | ||
| − | |||
| − | |||
<br><br> | <br><br> | ||
| + | </td> | ||
| + | <td> | ||
| + | [[image:benderlink_chiyodakeins_comengine_indicator.png|400px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
==[[image:Check.jpg|25px]] ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter == | ==[[image:Check.jpg|25px]] ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter == | ||
<table> | <table> | ||
| − | <tr> | + | <tr valign=top> |
<td width=400> | <td width=400> | ||
| Line 44: | Line 52: | ||
If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula: | If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula: | ||
<br><br> | <br><br> | ||
| − | (Rad Level 1) / 1.5<br><br> | + | <b>(Rad Level 1) / 1.5</b><br><br> |
If the Rad Level 1 value is zero, then Benderlink will use this formula:<br><br> | If the Rad Level 1 value is zero, then Benderlink will use this formula:<br><br> | ||
| − | (Rad Level 2) / 1.5<br><br> | + | <b>(Rad Level 2) / 1.5</b><br><br> |
| − | If both radius level values are zero, then Benderlink will set the diameter to 1 unit.<br><br>A non-zero diameter is important for communicating with ROMER DOCS software because DOCS will report a corrupted file if it senses a zero | + | |
| + | * If both radius level values are zero, then Benderlink will set the diameter to 1 unit.<br><br>A non-zero diameter is important for communicating with ROMER [[DOCS]] software because DOCS will report a corrupted file if it senses a zero diameter. (Some measuring center software packages, like [[VTube-LASER]] will continue with a zero diameter.)<br><br> | ||
| + | * If the radius stop is enabled, and Benderlink stops for input while the measuring center is performing a recall, then the recall process will time out if the new diameter is not entered within the time out period. | ||
</td> | </td> | ||
| Line 56: | Line 66: | ||
</tr> | </tr> | ||
</table> | </table> | ||
| + | <br><br> | ||
==OTHER PAGES== | ==OTHER PAGES== | ||
Latest revision as of 13:21, 15 November 2013
Revision 6.7Back to Benderlink for Chiyoda |
ENHANCED - New Serial Port COM Engine Available
|
This Benderlink can use either the new WinSoft COM engine for faster communications, or the older MarshallSoft COM engine for cases where the older engine works better. [Communications Setup] COM Engine=WinSoft or [Communications Setup] COM Engine=Marshallsoft
|
ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter
|
Benderlink can now stop the process and ask for input if a zero diameter is encountered. If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula:
|
OTHER PAGES
- Back to Benderlink for KEINS
- Back to Benderlink for Chiyoda
- Benderlink for Chiyoda FAQ
- About Chiyoda - See this page for control version information.