Difference between revisions of "VTube-LASER v1.57"
| (3 intermediate revisions by one user not shown) | |||
| Line 111: | Line 111: | ||
<br><br> | <br><br> | ||
| − | ===[[image:Check.jpg|25px]] ENHANCED: | + | ===[[image:Check.jpg|25px]] ENHANCED: Springback Compensation for Corrections === |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
| − | The | + | The springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone. |
| − | + | <br> | |
* For example, if the adjustment value for a 90 degree bend is found to be +3 degrees, then the springback compensation added to the bend is calculated based on 3 degrees, not 93 degrees. | * For example, if the adjustment value for a 90 degree bend is found to be +3 degrees, then the springback compensation added to the bend is calculated based on 3 degrees, not 93 degrees. | ||
| − | + | <br> | |
* The springback compensation works for both positive and negative adjustments. A positive adjustment will add springback. A negative adjustment will remove springback. | * The springback compensation works for both positive and negative adjustments. A positive adjustment will add springback. A negative adjustment will remove springback. | ||
| − | + | <br> | |
* VTube will not use springback for small adjustment values. The "Use springback compensation for bend adjustments greater than or equal to:" setting in the Bender Setup menu controls this. | * VTube will not use springback for small adjustment values. The "Use springback compensation for bend adjustments greater than or equal to:" setting in the Bender Setup menu controls this. | ||
</td> | </td> | ||
| Line 133: | Line 133: | ||
<br><br> | <br><br> | ||
| − | ===[[image:Check.jpg|25px]] NEW: Transfer Master LRA to Setup LRA Springback Compensation === | + | ===[[image:Check.jpg|25px]] NEW: Transfer Master LRA to Setup LRA with Springback Compensation === |
<table cellpadding=10> | <table cellpadding=10> | ||
| Line 181: | Line 181: | ||
* Added high precision angular decimal places value in System Option/Math | * Added high precision angular decimal places value in System Option/Math | ||
<br><br> | <br><br> | ||
| − | * Made Comments to display after the file has loaded and | + | * Made Comments to display after the file has loaded and the graphic is displayed on the screen. |
<br><br> | <br><br> | ||
* The BEST FIT alignment procedure is fine tuned to run about 6 times faster than in previous versions with no loss of accuracy. | * The BEST FIT alignment procedure is fine tuned to run about 6 times faster than in previous versions with no loss of accuracy. | ||
Latest revision as of 02:08, 13 January 2011
Revision 1.57Back to VTube-LASER |
NEW: Import Supravision Files
|
Supravision files are stored on Supravision-based measuring centers. Customers that migrate to VTube-LASER from Supravision will not lose any of their project data because you can use Supravision project files to setup VTube-LASER.
|
NEW: Transfer New Values in Supravision Protocol
|
New values are included in Supravision file transfers and Supravision Network transfers from benders (imports/exports/bender corrections):
|
|
NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master
|
You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender.
|
ENHANCED: Bender Setup Redesigned
|
The Bender Setup user interface menu was redesigned.
|
ENHANCED: Negative Lengths or Bend Angles are ZEROED
|
Bender Lengths and angles that calculate negative values are zeroed. |
ENHANCED: Springback Compensation for Corrections
|
The springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone.
|
NEW: Transfer Master LRA to Setup LRA with Springback Compensation
| When transferring data from the VTube MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero. |
NEW: Part Name in Toolbar
|
The current part name is now displayed in the toolbar below the VTube-LASER logo. |
NEW- Springback Values Transfer from Overbend
|
VTube-LASER can now receive springback data from Overbend with the press of a single button in the Overbend Calculator. |
ENHANCED - Other Changes
|
Other Pages
- Back to VTube-LASER