Difference between revisions of "VTube-LASER v1.57"
| (38 intermediate revisions by one user not shown) | |||
| Line 14: | Line 14: | ||
__NOTOC__ | __NOTOC__ | ||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW: Import Supravision Files=== | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | Supravision files are stored on Supravision-based measuring centers. Customers that migrate to VTube-LASER from Supravision will not lose any of their project data because you can use Supravision project files to setup VTube-LASER. | ||
| + | <br><br> | ||
| + | All appropriate values are imported. (See the Supravision Protocol entry below). | ||
| + | <br><br> | ||
| + | For old-style SV files created by the DOS version of Supravision, we can supply a [[SVFILE]] Converter program to convert the files/folders to newer long filenames. | ||
| + | </td> | ||
| + | <td width=300> | ||
| + | [[image:vtube-laser_1_57_importSV.jpg|300px]]. | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | <br><br> | ||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW: Transfer New Values in Supravision Protocol === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | New values are included in Supravision file transfers and Supravision Network transfers from benders (imports/exports/bender corrections): | ||
| + | <br><br> | ||
| + | |||
| + | </td> | ||
| + | <td width=300> | ||
| + | * Comment 1 | ||
| + | * Comment 2 | ||
| + | * Default Radius | ||
| + | * A End Offset | ||
| + | * B End Offset | ||
| + | * Tube Elongation Percentage | ||
| + | * Fixed Springback | ||
| + | * Proportional Springback | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | <br><br> | ||
===[[image:Check.jpg|25px]] NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master=== | ===[[image:Check.jpg|25px]] NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master=== | ||
| Line 22: | Line 65: | ||
You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender. | You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender. | ||
<br><br> | <br><br> | ||
| − | The toolbar on the right has a new button that allows you to RECALL MASTER XYZ from a bender to create the MASTER data in VTube. | + | The Bender Setup toolbar on the right has a new button that allows you to RECALL MASTER XYZ from a bender to create the MASTER data in VTube. |
<br><br> | <br><br> | ||
Before the transfer occurs, VTube will ask you to confirm that you mean to overwrite the MASTER data in VTube.<br><br> | Before the transfer occurs, VTube will ask you to confirm that you mean to overwrite the MASTER data in VTube.<br><br> | ||
| Line 35: | Line 78: | ||
<br><br> | <br><br> | ||
| − | ===[[image:Check.jpg|25px]] ENHANCED: Bender Setup | + | ===[[image:Check.jpg|25px]] ENHANCED: Bender Setup Redesigned=== |
| + | [[image:vtube-laser_1_57_bendersetup_bendernumber.jpg|500px]] | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
| Line 46: | Line 90: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
| − | |||
</td> | </td> | ||
</tr> | </tr> | ||
| Line 52: | Line 95: | ||
<br><br> | <br><br> | ||
| − | |||
===[[image:Check.jpg|25px]] ENHANCED: Negative Lengths or Bend Angles are ZEROED=== | ===[[image:Check.jpg|25px]] ENHANCED: Negative Lengths or Bend Angles are ZEROED=== | ||
| + | [[image:vtube-laser_1_57_bendersetup_zeroedlength.jpg|500px]] | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
| Line 62: | Line 105: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
| − | |||
</td> | </td> | ||
</tr> | </tr> | ||
| Line 69: | Line 111: | ||
<br><br> | <br><br> | ||
| − | ===[[image:Check.jpg|25px]] ENHANCED: Springback Compensation for | + | ===[[image:Check.jpg|25px]] ENHANCED: Springback Compensation for Corrections === |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
| − | The | + | The springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone. |
| + | <br> | ||
| + | * For example, if the adjustment value for a 90 degree bend is found to be +3 degrees, then the springback compensation added to the bend is calculated based on 3 degrees, not 93 degrees. | ||
| + | <br> | ||
| + | * The springback compensation works for both positive and negative adjustments. A positive adjustment will add springback. A negative adjustment will remove springback. | ||
| + | <br> | ||
| + | * VTube will not use springback for small adjustment values. The "Use springback compensation for bend adjustments greater than or equal to:" setting in the Bender Setup menu controls this. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
| − | [[image:vtube- | + | [[image:vtube-laser_1_57_bendersetup_automatic_adjustment_springback.jpg|300px]]<Br><br> |
| + | [[image:vtube-laser_1_57_bendersetup_automatic_adjustment_springback_limit.jpg|300px]]. | ||
</td> | </td> | ||
</tr> | </tr> | ||
| Line 84: | Line 133: | ||
<br><br> | <br><br> | ||
| − | ===[[image:Check.jpg|25px]] NEW: Transfer Master LRA to Setup LRA Springback Compensation === | + | ===[[image:Check.jpg|25px]] NEW: Transfer Master LRA to Setup LRA with Springback Compensation === |
<table cellpadding=10> | <table cellpadding=10> | ||
| Line 99: | Line 148: | ||
===[[image:Check.jpg|25px]] NEW: Part Name in Toolbar === | ===[[image:Check.jpg|25px]] NEW: Part Name in Toolbar === | ||
| − | + | [[image:vtube-laser_1_57_toolbar_filename.jpg|500px]] | |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
| Line 106: | Line 155: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
| − | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
| − | |||
<br><br> | <br><br> | ||
| Line 121: | Line 168: | ||
<td> | <td> | ||
[[image:vtube-laser_1_57_overbend_sendvaluestovtube.jpg|300px]]<br><br> | [[image:vtube-laser_1_57_overbend_sendvaluestovtube.jpg|300px]]<br><br> | ||
| − | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
| + | [[image:vtube-laser_1_57_overbend_transfer.jpg|500px]] | ||
| + | <br><br> | ||
| − | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] ENHANCED - Other Changes === |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
| − | + | * Added high precision angular decimal places value in System Option/Math | |
<br><br> | <br><br> | ||
| + | * Made Comments to display after the file has loaded and the graphic is displayed on the screen. | ||
| + | <br><br> | ||
| + | * The BEST FIT alignment procedure is fine tuned to run about 6 times faster than in previous versions with no loss of accuracy. | ||
| + | <br><br> | ||
| + | * Improvements/fixes to Supravision RECALL procedures. | ||
| + | [[image:vtube-laser_1_57_benderrecall.jpg|200px]]<br><br> | ||
</td> | </td> | ||
| − | <td | + | <td> |
| − | + | [[image:vtube-laser_1_57_highprec_angledecimalplaces.jpg|300px]]<br><br> | |
| − | + | [[image:vtube-laser_1_57_partcomments.jpg|300px]]<br><br> | |
| − | + | [[image:vtube-laser_1_57_bestfit_image.jpg|300px]]<br><br> | |
| − | + | ||
| − | + | ||
| − | + | ||
| − | + | ||
| − | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
| − | |||
| − | |||
| − | |||
| − | |||
Latest revision as of 02:08, 13 January 2011
Revision 1.57Back to VTube-LASER |
NEW: Import Supravision Files
|
Supravision files are stored on Supravision-based measuring centers. Customers that migrate to VTube-LASER from Supravision will not lose any of their project data because you can use Supravision project files to setup VTube-LASER.
|
NEW: Transfer New Values in Supravision Protocol
|
New values are included in Supravision file transfers and Supravision Network transfers from benders (imports/exports/bender corrections):
|
|
NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master
|
You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender.
|
ENHANCED: Bender Setup Redesigned
|
The Bender Setup user interface menu was redesigned.
|
ENHANCED: Negative Lengths or Bend Angles are ZEROED
|
Bender Lengths and angles that calculate negative values are zeroed. |
ENHANCED: Springback Compensation for Corrections
|
The springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone.
|
NEW: Transfer Master LRA to Setup LRA with Springback Compensation
| When transferring data from the VTube MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero. |
NEW: Part Name in Toolbar
|
The current part name is now displayed in the toolbar below the VTube-LASER logo. |
NEW- Springback Values Transfer from Overbend
|
VTube-LASER can now receive springback data from Overbend with the press of a single button in the Overbend Calculator. |
ENHANCED - Other Changes
|
Other Pages
- Back to VTube-LASER