Difference between revisions of "VTube-LASER v1.55"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED - Measure Setup Menu)
(25px NEW: Radius Segment Scan Method)
Line 21: Line 21:
 
Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.
 
Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.
 
<br><br>
 
<br><br>
The Set Segment Scan Count box (see below) allows you to enter from 3 to 10 segments to measure per arc.
+
The new Set Segment Scan Count box allows you to enter from 3 to 10 segments to measure per arc. (Also see the enhanced Measure Process menu below.)
 
<br><br>
 
<br><br>
  

Revision as of 04:13, 4 January 2011

Vtube-laser logo.jpg

Revision 1.55

Back to VTube-LASER

Vtube-laser screen 1 54.jpg


Check.jpg NEW: Radius Segment Scan Method

Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.

The new Set Segment Scan Count box allows you to enter from 3 to 10 segments to measure per arc. (Also see the enhanced Measure Process menu below.)

Vtube-laser radius segment measurement graphic.jpg

Vtube-laser radius segment scan count.jpg

Check.jpg ENHANCED - Measure Process Menu

The enhanced Measure Process menu is reorganized. The menu includes the new Straight Count box - which was moved from the Measure Setup menu.

The menu also includes a new field for the new Radius Segment Scan - segment count.

Vtube-laser measureprocess v1 55.jpg



Check.jpg ENHANCED - Measure Setup Menu

The Measure Setup program is condensed because the Straight Count setting has been moved to the Measure Process menu for consistency.

Vtube-laser measuresetup v1 55.jpg