Difference between revisions of "VTube-LASER v1.54"
| (31 intermediate revisions by one user not shown) | |||
| Line 1: | Line 1: | ||
<table> | <table> | ||
<tr cellpadding=10> | <tr cellpadding=10> | ||
| − | <td width= | + | <td width=225> |
| − | [[image:vtube-laser_logo.jpg| | + | [[image:vtube-laser_logo.jpg|200px]] |
| − | + | ==Revision 1.54== | |
| + | Back to [[VTube-LASER]] | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
| Line 10: | Line 11: | ||
</tr> | </tr> | ||
</table> | </table> | ||
| − | |||
| − | |||
__NOTOC__ | __NOTOC__ | ||
| Line 20: | Line 19: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
| − | The digital readout was added to give feedback for the arm motion | + | The digital readout was added to give feedback for the arm motion and arm diagnostics.<br><br> |
| + | [[image:vtube-laser_dro.jpg|150px]] | ||
</td> | </td> | ||
<td> | <td> | ||
[[image:vtube-laser_dro_closeup.jpg|300px]]<br> | [[image:vtube-laser_dro_closeup.jpg|300px]]<br> | ||
| − | |||
</td> | </td> | ||
</tr> | </tr> | ||
| Line 40: | Line 39: | ||
<td> | <td> | ||
[[image:vtube-laser_viewcontrol.jpg]] | [[image:vtube-laser_viewcontrol.jpg]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | <br><br> | ||
| + | |||
| + | |||
| + | |||
| + | ===[[image:Check.jpg|25px]] ENHANCED - Automatic Clear Measure Process After End B Measure === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | Now the Measure Tube process automatically clears from the screen after the data from End B is collected<br><br> | ||
| + | This causes the tube measure control to close automatically. | ||
| + | </td> | ||
| + | <td> | ||
| + | [[image:vtube-laser_tubemeasurecontrol_endb.jpg|300px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | <br><br> | ||
| + | |||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW - Realtime Calculation of Intersection === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | Intersection points are calculated in realtime and displayed on the screen as orange points. | ||
| + | <br><br> | ||
| + | This means that they are calculated as soon as possible during the measurement. This helps make the MOVE command and other commands that rely on realtime information possible. | ||
| + | </td> | ||
| + | <td> | ||
| + | [[image:vtube-laser_intersectionpoints.jpg|300px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | <br><br> | ||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW - Realtime Calculation of Intersection Error === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | Each point is checked for a Maximum Intersection Error which is set in the Measuring 2 tab of the System Options menu. The default tolerance is 2mm, or 0.078 inches. | ||
| + | <br><br> | ||
| + | If an intersection error calculates beyond the tolerance, then VTube stops and warns the operator of a potential problem, then allows him to remeasure or continue to the next straight. | ||
| + | </td> | ||
| + | <td> | ||
| + | [[image:vtube-laser_intersection_error_idialog.jpg|300px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | <br><br> | ||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW - Code Signing of VTube.exe === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | The VTube program is now code signed in order to comply with the Microsoft Authenticode requirements. | ||
| + | <br><br> | ||
| + | *Ensures authenticity - users that they know where the code came from | ||
| + | *Ensures integrity - verifies that code has not been tampered with since publication | ||
| + | *Reduces error messages and security warnings on download and installation on Windows Vista and Windows 7 computers | ||
| + | </td> | ||
| + | <td> | ||
| + | [[image:vtube-laser_codesigned.jpg|300px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | <br><br> | ||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW - Verified Bluetooth Compatible === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | VTube-LASER is verified to work with the FARO ScanArm Bluetooth connection. This allows connection to the FARO arms within 30 feet of the VTube-LASER computer without cables. | ||
| + | </td> | ||
| + | <td> | ||
| + | [[image:vtube-laser_bluetooth.jpg|300px]]<br> | ||
| + | [[image:vtube-laser_systemtray_bluetooth.jpg|300px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | <br><br> | ||
| + | |||
| + | ===[[image:Check.jpg|25px]] ENHANCED - VTube-LASER Setup Files Include the FARO USB Setups === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | <td width=200> | ||
| + | The VTube-LASER installation setup now includes the FARO USB drivers for either 32 or 64 bit computers.</td> | ||
| + | <td> | ||
| + | [[image:usb_connector.jpg|300px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | ===[[image:Check.jpg|25px]] NEW - PDF Printer Driver Setup Included in Installation === | ||
| + | |||
| + | <table cellpadding=10> | ||
| + | <tr valign=top> | ||
| + | |||
| + | <td width=200> | ||
| + | Now every VTube-LASER installation can also install a PDF printer driver for easy output of inspection reports in the PDF format. This lets operators create historical fixed reports with static date/time for a record of qualification of the tube shape. | ||
| + | <br><br> | ||
| + | The two programs installed are the CutePDF Writer printer driver and the GPL Ghostscript program - which is required by the CutePDF Writer print driver to operate. | ||
| + | </td> | ||
| + | <td> | ||
| + | [[image:gpl_ghostscript_installation.jpg|300px]]<br> | ||
| + | [[image:cute_pdf_installation.jpg|300px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
Latest revision as of 23:40, 28 December 2010
Revision 1.54Back to VTube-LASER |
NEW - DRO: Digital Readout
|
The digital readout was added to give feedback for the arm motion and arm diagnostics. |
ENHANCED - Arm as Mouse Feature
|
The automatic "arm as a mouse" feature is enhanced so that the arm can be used as a mouse whenever a dialog displays on the screen - even in the middle of tube measurement. As soon as the dialog closes and measuring resumes, the arm as a mouse feature switches off.
|
ENHANCED - Automatic Clear Measure Process After End B Measure
|
Now the Measure Tube process automatically clears from the screen after the data from End B is collected |
NEW - Realtime Calculation of Intersection
|
Intersection points are calculated in realtime and displayed on the screen as orange points.
|
NEW - Realtime Calculation of Intersection Error
|
Each point is checked for a Maximum Intersection Error which is set in the Measuring 2 tab of the System Options menu. The default tolerance is 2mm, or 0.078 inches.
|
NEW - Code Signing of VTube.exe
|
The VTube program is now code signed in order to comply with the Microsoft Authenticode requirements.
|
NEW - Verified Bluetooth Compatible
|
VTube-LASER is verified to work with the FARO ScanArm Bluetooth connection. This allows connection to the FARO arms within 30 feet of the VTube-LASER computer without cables. |
ENHANCED - VTube-LASER Setup Files Include the FARO USB Setups
| The VTube-LASER installation setup now includes the FARO USB drivers for either 32 or 64 bit computers. |
NEW - PDF Printer Driver Setup Included in Installation
|
Now every VTube-LASER installation can also install a PDF printer driver for easy output of inspection reports in the PDF format. This lets operators create historical fixed reports with static date/time for a record of qualification of the tube shape.
|
Other Pages
- Back to VTube-LASER
