Difference between revisions of "VTube Communication for SOCO"

From ATTWiki
Jump to: navigation, search
(Communications Setup with the SOCO Bender)
(Setup Benderlink inside of VTube-STEP or VTube-LASER)
Line 48: Line 48:
 
==Setup Benderlink inside of VTube-STEP or VTube-LASER==
 
==Setup Benderlink inside of VTube-STEP or VTube-LASER==
  
 +
<table>
 +
<tr valign=top>
 +
<td width=500>
  
 
*Enter the VTube System Options menu.
 
*Enter the VTube System Options menu.
*Click on
+
*Enter the Measure 2 tab menu.
 
+
*Enter the Benderlink Setup menu.
  
 +
</td>
 +
<td width=300>
 
[[image:VTube System Options Benderlink Network Button.png|500px]]
 
[[image:VTube System Options Benderlink Network Button.png|500px]]
 +
</td>
 +
</tr>
 +
</table>
  
 
==How to SEND MASTER XYZ Data to the SOCO Control==
 
==How to SEND MASTER XYZ Data to the SOCO Control==

Revision as of 19:09, 9 September 2016

VTube-STEP and VTube-LASER Communications with SOCO Benders

SOCO Logo with Bender.png



Protocol

VTube-STEP can export Supravision data to SOCO benders using the SOCO SVNet protocol.

VTube-LASER, the version of VTube that connects to a FARO measuring center arm, can send measured data to the SOCO control for corrections.

Faro scanner v6.png

VTube-LASER to Soco XYZ.png

Communications Setup with the SOCO Bender

  • Connect the SOCO bender to the network using a standard Ethernet cable. SOCO computers can be accessed through the lower front of the operator station. Run the cable through the small side door on the right, and up to the computer system. The SOCO control computer will have Ethernet ports available for connection.

  • Setup a shared network location either in the SOCO windows control or in a network path on your network.

  • In the SOCO YBC screen, press the measuring center button.

  • Enter the shared network path in the Exchange Directory field. This path name cannot be a UNC name (like \\192.168.0.2\VTube\). It must be a path with a drive and a path that follows. If you must network to a location on the network, then map a drive letter to that location, and use the mapped drive letter in this field.

  • Enter the bender number. Each bender number needs to have a unique number in the network. The bender number must be 1 or higher. Don't use "0" for the bender number, because VTube requires a bender number that is at least 1.

  • Activate the SV/SV Network communications. Touch the checkbox field until it shows a check mark (see the image on the right).

Soco Measuring Center Setup.png

Setup Benderlink inside of VTube-STEP or VTube-LASER

  • Enter the VTube System Options menu.
  • Enter the Measure 2 tab menu.
  • Enter the Benderlink Setup menu.

VTube System Options Benderlink Network Button.png

How to SEND MASTER XYZ Data to the SOCO Control

You can import data into VTube-LASER



Using VTube-LASER to send NEW MASTER Data to YLM Benders

The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer.

For a NEW TUBE, the YLM takes in VTube MASTER Supravision LRA data in a Supravision file.



Follow these steps at VTube-LASER to Send a NEW TUBE SETUP to a YLM Bender

STEP 1
Switch to the MASTER TUBE window and press the FILE tab.

STEP 2
Save the Supravision file.

STEP 3
Move to the YLM control and follow the steps below to import the new data.

Vtube-laser-1.96 SupravisionExportMenu Master.png

Vtube-laser-1.96 SaveMasterSupravisionData.png

Follow these steps at the YLM CONTROL to import the MASTER data from VTube-LASER

STEP 1

In the YLM control, clear the YBC data. (Note:Clearing is optional. It is not always necessary - but seems to keep data from overlapping between older and newer setups.)

YLM YBC Screen.png

STEP 2


In the YLM YBC menu, click on CORRECTION.

Note: This button can be disabled on some controls and must be enabled in the setup. Contact Joe Seibel ([email protected]) of this button is disabled so that he can give you instructions for enabling the feature.

Ylm ybc correction button.png

STEP 3

In the lower right corner of the screen, select the drive and path then explore for and select the $$$ file that was created by VTube-LASER.

YLM Import Screen.jpg

STEP 4

In the YLM YBC menu, click on IMPORT. (Do not click "COMPARE" - as that is for corrections.)

YLM YBC NewImport.png

STEP 5

Press the Exit menu close button in the lower right corner of the screen.

YLM YBCCorrections exit.png

STEP 6

In order to exit the YBC screen, you might need to double tap on the teach mode button in order to turn on teach mode. Then double tap on the sequences icon on the top of the sequences column. Reset the sequences.

YLMTeachModeAndSequence.png




VTube-LASER CORRECTION Steps for YLM Benders

The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer.

The YLM control handles corrections differently than any other control. This is how it is unique:

  • First, for a CORRECTION, the YLM takes in VTube MEASURED Supravision LRA data. To make a correction to a YLM bender, it is important to send ONLY this data. The standard correction process will not work with the YLM.

  • Second, the YLM uses the correction in the opposite way in its standard setup when taking in the MEASURED data and comparing it to its MASTER or NOMINAL data. For example, if the Measured data shows 1 degree overbent, then the YLM correction procedure will send that bend one MORE degree.



Handling Opposite Corrections

There are two ways to overcome the opposite correction problem:

1 - Use a special INVERSION checkbox in the VTube Supravision Export menu. Only use this inversion switch when sending measured data for correction.

2 - Have the YLM technician change the internal low level setting in the YLM control that makes the correction be apply in the normal way.

Follow these steps at VTube-LASER to Correct a YLM Bender

STEP 1

Switch to the MEASURED TUBE window and press the FILE tab.

VTube-Laser-1.96 SaveMeasuredTubeData.png

STEP 2

Most YLM benders use the pure MEASURED data for corrections. However, some YLM benders need the MEASURED data changed into the CORRECTED data - and the CORRECTIONS are always made based on the MASTER data (not the existing data in the bender). We call this "YBC Correction Inversion".

If you find that the corrections move in the wrong direction on a YLM, then check the inversion check box. The inversion check box will only display if VTube knows you are saving MEASURED data to a Supravision file.

Vtube-laser-1.96 SupravisionExportMenu.png

STEP 3

Save the Supravision file.

STEP 4

Move to the YLM control and follow the steps below to import the correction.



Follow these steps at the YLM CONTROL to import the measured data from VTube-LASER

STEP 1

In the YLM YBC menu, click on CORRECTION.

Note: This button can be disabled on some controls and must be enabled in the setup. Contact Joe Seibel ([email protected]) of this button is disabled so that he can give you instructions for enabling the feature.

Ylm ybc correction button.png

STEP 2

Search for and select the $$$ file that was created by VTube-LASER.

STEP 3

Select COMPARE to bring the data into the YLM control. The COMPARE button will only display when a file is selected.

NOTE: DO NOT press the IMPORT button for corrections. Pressing IMPORT will make the correction data the nominal data - which would be incorrect.

YMC YBC Correction CompareButton.png

STEP 4

Press the menu close button in the lower right corner.

YLM YBCCorrections exit.png

Shutdown to Edit the Windows Setup

To shutdown the YLM software to configure Windows settings:

  1. Press the Shutdown button.

  2. Press "NO" for shutdown.

  3. Type "12345" and OK in the numeric keypad.

  4. YLM will close without shutting down the computer.