Difference between revisions of "VTube-STEP v1.81.4"

From ATTWiki
Jump to: navigation, search
(25px NEW: Graphic Point Labels in the Model)
(25px NEW: Graphic Point Labels in the Model)
Line 27: Line 27:
 
<td width=400>
 
<td width=400>
 
   
 
   
[[image:vtube-laser-1.81.4.graphicpointlabels2.jpg|400px]]
+
[[image:vtube-step-1.81.4.graphicpointlabels2.jpg|400px]]
  
 
* The new graphic point labels display on the tube model.<br><br>
 
* The new graphic point labels display on the tube model.<br><br>
Line 37: Line 37:
 
<td width=300>
 
<td width=300>
 
[[image:vtube-step-1.81.4_graphicpointlabels.jpg|300px]]<br>
 
[[image:vtube-step-1.81.4_graphicpointlabels.jpg|300px]]<br>
[[image:vtube-laser-1.81.4_reportswithlabels.jpg|300px]]<br>
+
[[image:vtube-step-1.81.4_reportswithlabels.jpg|300px]]<br>
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 16:58, 28 March 2013

Vtube-step logo.jpg

Revision 1.81.4

Vtube-step 1.79.jpg




Check.jpg NEW: Graphic Point Labels in the Model

Vtube-step-1.81.4.graphicpointlabels2.jpg

  • The new graphic point labels display on the tube model.

  • They show the end labels and the intersection point labels in balloons that surround the part.

  • The graphics labels are now included in reports.

  • The label fonts can be controlled in the new Parametric Tube control window.

Vtube-step-1.81.4 graphicpointlabels.jpg
Vtube-step-1.81.4 reportswithlabels.jpg



Check.jpg ENHANCED: Guide Window Placement

Vtube-step 1.81.4 guideonscreen.jpg

VTube-STEP Collection Guide helps users know what step to take next. This Guide window has been moved to the upper right corner so that it doesn't sit on top of the image.



Check.jpg ENHANCED: Faster Redraw When Changing From Orbit to View

Changing from Orbit to View modes with a right click could create three slow flashes of the graphic window. This has been resolved.

Check.jpg ENHANCED: Now Send Benders the Supravision Data in Current Linear Units

Previous VTube-STEP versions would always output Supravision data to benders in millimeters. This version of VTube-STEP outputs Supravision data to benders using the current linear unit being used in VTube.


Check.jpg FIX: The SVNET Path Value Is Now Always Used to Send Bender Data to the Correct Path

Previous versions would require two or more presses of the SEND or TEST button for the correct path to be used. This version fixes that problem by using the path the first time.

Vtube-step svnet path.jpg


Check.jpg ENHANCED: Disable/Enable Ribbon Twist Angles Button

When Ribbon (tang) stripes are not present in memory, VTube-STEP will keep the "Save Bender File with Riboon Twist Angles" button disabled.

Vtube-step saveribbontwistangles disabled.jpg

Other