VTube-LASER UniScan Automatic Laser Separation

From ATTWiki
Revision as of 01:33, 9 March 2019 by Mcone (Talk | contribs)

Jump to: navigation, search

Vtube-laser logo 1.96.png


UniScan Automatic Separation Tutorial


Vtube-laser v2.7 screenshot.png

Contents


Ra8 stripes.png


About the AUTOMATIC LASER SEPARATION Method for UniScan Mode

The AUTOMATIC LASER SEPARATION method allows VTube-LASER to automatically control the separation distance between laser stripes based on the known MASTER tube length.

This allows VTube-LASER to lay stripes closer on shorter straights to collect more data - while making VTube spread out stripes on longer sections - automatically.

This method ensures even distribution of stripes for all lengths in the same tube without changing the laser separation distance on the fly.

Vtl v2.9.18 AutomaticLaserSeparation Graphic.png



How AUTOMATIC LASER SEPARATION Method Works

  • This mode only works with parts that have MASTER data.

  • The FACTOR value is multiplied against the current MASTER length to get a new separation distance. The valid ranges are 0 to 0.5. If you use 0.5, then VTube-LASER will attempt to lay two stripes per straight. A recommended starting value is 0.025 (40 stripes per straight).

  • If a part does not have MASTER data (like for Reverse Engineering), then the regular UniScan Cylinder Separation Distance value is used.

  • If the separation distance is ever less than 0.004" (100 microns), then the value reverts to 100 microns.

  • If the MASTER length is less than or equal to ZERO, then the separation value reverts to the regular UniScan Cylinder Separation Distance value.

Vtl v2.9.18 AutomaticLaserSeparation LargeBanner.png




Real-time Separation Distance Reported

The measure guide window indicates the current real-time separation distance.

Vtl v2.9.18 AutomaticLaserSeparation tubemeasureguide.png

Other Pages