VTube-LASER v1.94

From ATTWiki
Revision as of 16:16, 2 September 2014 by Mcone (Talk | contribs)

Jump to: navigation, search

Vtube-laser logo.jpg

Revision 1.94


Vtube-laser 1.89 mainscreen.png






The major change in this version is the addition of the Tube Data Storage feature - which can permanently store the current tube data at any time.

Foundational Features

  • VTube automatically saves the date-time stamped tube data at alignment after a measure.

  • VTube allows you to copy the current tube data into storage at any time.

  • Values stored are:
    • General Part Setup Data
    • MASTER tube data
    • MEASURED tube data
    • MEASURED Aligned tube data

  • The complete alignment and deviation data is also stored - so you can even compare the deviation data from multiple tube sets in the Expanded grid or in Excel or Word.

  • We've tested VTube with hundreds of stored tubes. The Tube Data Storage menu reports the number of parts in memory, and the amount of memory the parts consume.



Check.jpg NEW: Toolbar Button - Tube Data Storage

Enter Tube Data Storage with the toolbar button at the top of the VTube-LASER screen.

Vtube-laser 1.94 tubedatastorage toolbar button.png

Check.jpg NEW: Tube Data Storage Menu

The new Tube Data Storage menu allows you to view historical time-stamped part measures. Thew data can be combined into one expanded grid for export to Word or Excel. This is useful for GR&R studies because it takes VTube only a few seconds to combine scores of selected historical tube data sets.

Screen Controls 1

Vtube-laser-1.94 tubedatastorage datacontrols1.png

Screen Controls 2

Vtube-laser-1.94 tubedatastorage datacontrols2.png

Expanded Grids with Multiple Parts

The expanded grids can hold multiple parts (whichever part is selected with checks in the Tube Data Storage).

Vtube-laser-1.94 tubedatastorage expanded tangents.png



Export the Part List

Export the entire part list to Word or Excel.

Vtube-laser-1.94 tubedatastorage export partlist.png


Copy Any Part Set Back Into VTube for Reanalysis

Copy any single part set back into VTube in order to perform any VTube operation on the historical data. For example, you could change and test a different alignment method on an older measure and report the results with a regular report.

Vtube-laser-1.94 tubedatastorage copytube into vtube.png

Check.jpg Other Changes

  • When VTube performs an alignment, it will now automatically switch to the Tangent point deviation menu to show updates in real-time.

  • The Intersection Deviations now update in real-time during a best fit. Switch to this menu any time during the alignment to see the numbers change.

  • A new "array_xyz_int_dev" parameter for report templates allows for 3D deviations to display in reports.

  • VTube now stores up to 10 undo states.

  • The undo action now refreshes the screen in VTube-LASER to clearly show that Undo just occurred.

  • Expanded grids no longer remove the previous Windows clipboard data when transferring.

  • All the Tube Data Storage memory was added to the VTube project file structure so that it always stores the data to the VTP files.


Other