NEW: End Scan Outlier Detection
The end scan procedures in VTube-LASER are now enhanced to detect and remove outlier points in an end-scan.
In the context of VTube-LASER, an "outlier" is a point that falls outside the space of the actual surface being scanned.
The image at the right shows a side view of the result of an end-scan of a tube. The LLP (laser line probe) is positioned above the tube at the top of this image and is pointed downward in the direction of the left black arrow. The laser is moving downward along its path from the probe. It is then reflected back to the receiver of the scanner in the path of the right arrow.
Most of the points fall on the surface of the outside of the tube, inside the tube, or wall of the tube. However, there is also an outlier point present (enclosed in the red lines at the top). It cannot possibly part of the diameter. (These points were formed from a higher-than-normal reflective points on the inside of the diameter.
The outlier point is detected and then removed from the list of possibilities automatically because it is not close enough to the diameter or wall of the diameter.
This ensures repeatability of the end-scan process.
|
|
REPAIR: Mix ball probe and laser measurement
Using ball probe measurements on the end scans and and laser measurements in the cylinder straights now offsets the ball radius point properly in every case.
|
|
ENHANCEMENT- Part Name is Used as Filename When Part Name Changes
In previous versions, the part name was used as the filename only if the previous filename was empty.
Now - when the part name changes, the part name is used as the initial filename in the Save dialog. |
|
ENHANCED- Linear Units Now Set By Single Large Button
In previous versions, the linear units radio buttons were not reliable in setting the proper state.
Plus they were too small to easily press.
This version removes these radio buttons and uses an large button with either an M or an I that toggles the state.
These buttons can also be localized. The M and I can be changed to other Unicode characters for other languages. |
Old Interface:
New Interface:
|
REPAIR- Laser Active Initialization
In previous versions, VTube required the operator to enter Measure Setup at least one time when coming into Laser Mode in order to setup the Laser active mode.
This has been corrected in this version. It is no longer necessary to enter measure setup if you know the setup is correct. |
|
Other Changes
- The report window now requires an operator to close the window before using any other part of VTube.
- The print preview window buttons are re-arranged so that they are larger and easier to press. The Print button is moved to the right side of the window.
- If VTube changes from cylinder fit to centerline projection mode during a measurement, VTube will now always consider the measure a cylinder fit failure.
|
|
Changes to VTube-STEP
Issues with this version fixed in next version