It is also possible to move the tube if you attach the targets securely to the tube, then use the leapfrog feature. For example, you can use a standard metal spring clamp to attach to the tube, then place the magnetic target on the clamp handle.
The Steps for Tube Move
Place at least 3 targets on the tube. The three targets should not form a single line.
Press the LEAP button in the guide window on the left.
Measure the targets with the ball probe. Press the green button to measure each target.
Press the red button to finish the initial measure.
Move the tube and the targets to the new position relative to the arm.
Measure the targets with the ball probe. Press the green button to measure each target.
Press the red button to finish the measure.
The move is complete. Continue measuring where you left off before.
|