This page describes the use of the VTube-STEP and VTube-LASER to STAR bender new data setup and corrections using the STAR SVNet protocol. |
Back to VTube-LASER
Network Protocol
VTube-STEP and VTube-LASER use a modified Supravision Network protocol to send new part data and bender part corrections to STAR EVO benders. |
STAR SVNet Data Protocol Information
These are important facts to know about this protocol.
|
BENDERLINK SETUP STEPS FOR VTUBE-LASER
STEP 1: Enter the SYSTEM OPTIONS Menu in VTube
|
STEP 2: Setup the Benderlink Network Grid for STAR SVNet Protocol
|
How to SEND CORRECTION Data to the STAR Control from VTube-LASER
STEP 1 - Bend the Tube
Bend the tube in the STAR bender. |
STEP 2 - Measure the tube with VTube-LASER
Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape. |
STEP 3 - Enter BENDER SETUP
Click on the BENDER SETUP button in the Navigation Pane. |
STEP 4 - Choose the BENDER NUMBER
Set the correct bender number at the top of the window. |
STEP 5 - COPY the Data from VTube-LASER's Main Memory
If this is the first correction, then the Bender Setup screen may show no data. If this is the case, then it is necessary to update the Bender Setup screen from VTube-LASER's main memory like this:
|
STEP 6 - OPTIONAL STEP - You Can Manually Change the ADJUSTMENT Values
You can manually change the ADJUSTMENT values before sending corrections if you want to. Some users like to set the first and last Length adjustment to zero in order to keep the start position of the carriage in the same place - for when they have extra length on the ends. |
STEP 7 - Send Corrections to the STAR
Press "Auto SEND Bender CORRECTIONS" to send the orange column data to the bender. |
STEP 8 - Confirm that the Blue Column Data is Correct
VTube-LASER will ask you to confirm that the original blue-column data matches the data in the STAR bender. |
STEP 9 - The SEND to BENDER Complete Window
A window should appear for a few seconds indicating that the send to the Bender is complete. |
STEP 10 - IMPORT the Correction Data at the STAR Control
Move to the STAR control and import the file using the steps in the import document from STAR TECNOLOGY: |
STEP 11 - REPEAT STEPS 1 THROUGH 10
Bend the corrected tube starting in Step 1, then measure it again (Step 2) and follow the rest of the steps until the part is within tolerance. |