Difference between revisions of "VTube-LASER ROMER RDS Performance Recommendations"
(→RDS Performance Notes) |
(→Other Pages) |
||
Line 162: | Line 162: | ||
</table> | </table> | ||
<br><br> | <br><br> | ||
+ | |||
+ | ==RDS Performance Notes== | ||
+ | |||
+ | <table width= 900> | ||
+ | <tr cellpadding=10> | ||
+ | <td width=300> | ||
+ | When idling, the RDS service requires only 1 to 5 percent of the CPU usage.<br><br> | ||
+ | When scanning, RDS can take up to 20% of the CPU usage.<br><br> | ||
+ | It is very important that other processes are not causing the CPU usage to rise to 100%. If you have other services that send the CPU over 50%, you may experience less than ideal scanning responses. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:RDS Popup Menu.png|200px]] | ||
+ | </td> | ||
+ | |||
+ | </tr> | ||
+ | |||
+ | <table width= 900> | ||
+ | <tr cellpadding=10> | ||
+ | <td width=300> | ||
+ | You can watch the CPU usage in the Windows Task Manager.<br><br> | ||
+ | In Windows 10, to display the Task Manager, right click on the task bar at the bottom of the Windows desktop and choose "Task Manager" from the popup menu. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:RDS in Task Manager.png|600px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | |||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
==Other Pages== | ==Other Pages== |
Revision as of 16:58, 18 July 2018
Information about RDS performance with VTube-LASER
|
See also RDS Versions for ROMER Scanners
About ROMER RDS - (ROMER Device Software)
ROMER RDS (ROMER Device Software) is a software system that interconnects software like VTube-LASER to any HEXAGON measuring device that uses the RDS software. See this page for details all the different arms that RDS can connect VTube-LASER to: RDS Versions for ROMER Scanners
|
Recommended RDS Computer IP Setup
The ROMER scanners communicate with the computer with two cable connections:
The newer RS4 ROMER power packs (on the back of the base of the arm) can automatically serve an IP address to the computer using DHCP. |
Recommended RDS Control Panel Setup
This is how we recommend that you setup the RSx menu in the RDS Control Panel for VTube-LASER.
|
We recommend that you turn the ROMER sound off in General parameters. |
ROMER Ball Probe Support
All ball probe systems on devices that run through RDS are compatible with VTube-LASER. (VTube-LASER can use the LASER or the ball probe.) |
ROMER Driver Downloads
RDS 4.2.1 and newer work well. Version 4.2.2 and newer has anti-outlier (anti-flyer) algorithms for highly reflective surfaces. |
How to Determine Your Current RDS Version
Left click on the System Tray icon. |
|
Right click on the measuring center icon. |
|
Left click on About. |
|
The RDS About window will display. |
RDS Performance Notes
When idling, the RDS service requires only 1 to 5 percent of the CPU usage. |
You can watch the CPU usage in the Windows Task Manager. |
Other Pages