Difference between revisions of "Recommendations for FARO Arms"
(→FARO Version 2 Scanner) |
(→FARO ES Scanner) |
||
(8 intermediate revisions by one user not shown) | |||
Line 42: | Line 42: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | <br><br> | ||
==FARO ES Scanner== | ==FARO ES Scanner== | ||
Line 51: | Line 52: | ||
* It's performance is much better than any previous versions, but (unlike the HD scanner) you may have to deal with lighting issues with this scanner. Sometimes external lighting can interfere with this scanner. You may need to move the arm to a darker room to measure. Skylights from external sunlight will probably make scanning impossible in our experience. | * It's performance is much better than any previous versions, but (unlike the HD scanner) you may have to deal with lighting issues with this scanner. Sometimes external lighting can interfere with this scanner. You may need to move the arm to a darker room to measure. Skylights from external sunlight will probably make scanning impossible in our experience. | ||
+ | |||
+ | |||
+ | * It is often necessary to run this scanner in FIXED exposure mode - rather than AUTO. This is a bit of an inconvenience to the customer. But customers don't seem to mind anyway. | ||
Line 64: | Line 68: | ||
<td> | <td> | ||
+ | |||
+ | <br><br> | ||
[[image:FARO_LLP_v5.png|300px]] | [[image:FARO_LLP_v5.png|300px]] | ||
</td> | </td> | ||
Line 69: | Line 75: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | |||
+ | <br><br> | ||
==FARO Version 4 Scanner== | ==FARO Version 4 Scanner== | ||
Line 78: | Line 87: | ||
* This was the first scanner from FARO to have a vertical laser line. If you were to point the laser at a wall with the grip pointing toward the floor, then you will see a vertical laser line on the wall. The effect is to give the sensation that you are spray-painting the surface with the laser with a left to right or right to left motion relative to the handle. | * This was the first scanner from FARO to have a vertical laser line. If you were to point the laser at a wall with the grip pointing toward the floor, then you will see a vertical laser line on the wall. The effect is to give the sensation that you are spray-painting the surface with the laser with a left to right or right to left motion relative to the handle. | ||
+ | |||
+ | |||
+ | |||
+ | * '''This scanner works best with the scanner exposure algorithm set to FIXED MODE. Automatic modes will not work well when measuring tube shapes.''' | ||
</td> | </td> | ||
Line 112: | Line 125: | ||
<tr> | <tr> | ||
<td> | <td> | ||
+ | |||
+ | * This scanner does not work with Edge arms. | ||
+ | |||
+ | |||
* This is the oldest scanner that we know about. (We've never seen version 1.) A few customers use it in applications that don't require a lot of accuracy. It works - but it cannot be run well in a room with standard factory lighting. Also, expect to surface-coat (see [[Surface Spray]]) any slightly reflective tubes. | * This is the oldest scanner that we know about. (We've never seen version 1.) A few customers use it in applications that don't require a lot of accuracy. It works - but it cannot be run well in a room with standard factory lighting. Also, expect to surface-coat (see [[Surface Spray]]) any slightly reflective tubes. | ||
Line 120: | Line 137: | ||
* '''This scanner only works with the scanner exposure algorithm set to FIXED MODE. Automatic modes will not work well when measuring tube shapes.''' | * '''This scanner only works with the scanner exposure algorithm set to FIXED MODE. Automatic modes will not work well when measuring tube shapes.''' | ||
− | |||
− | |||
</td> | </td> |
Latest revision as of 16:52, 10 May 2018
This page answers questions about which FARO arm to use in your tube measuring application. We've listed the different options in this page so that you know what to consider.
Contents |
Arm Repeatability and Ball Probe Accuracy
This chart shows the arm repeatability for the different FARO arm models. FARO arm sizes is listed in VOLUME - which means the diameter of the sphere volume that the arm can reach in total. So the length of the arm 1/2 the volume value.
WORKING VOLUME | ||||||
---|---|---|---|---|---|---|
1.2 M (4 foot) | 1.8 M (6 foot) | 2.4 M (8 foot) | 2.7 M (9 foot) | 3 M (10 foot) | 3.7 M (12 foot) | |
Edge | 0.024 (0.00094) | 0.029 (0.0010) | 0.064 (0.0025) | |||
Prime | 0.016 (0.0006) | 0.019 (0.00075) | 0.024 (0.00094) | 0.042 (0.0017) | 0.060 (0.0023) | |
Fusion | 0.036 (0.0014) | 0.043 (0.0017) | 0.074 (0.0029) | 0.104 (0.0040) | ||
REPEATABILITY mm (in) Performance specifications according to B89.4.22 |
These repeatability values are also referred to by FARO account managers as "accuracy" values.
Ball Probe Accuracy
You can expect the ball probes to perform close to the values listed in the grid above when the arm is setup and used properly.
Laser Line Probe Accuracy
In general, you can take these values are double them to get the expected accuracy of the laser scanners. FARO also calls these scanners "Laser Line Probes" because they scan using one line or "stripe" of laser at a time. The different scanners have a huge variance in performance. Choosing the right scanner is very important. (More important than choosing the right arm in our opinion.)
FARO HD Scanner
|
FARO ES Scanner
|
FARO Version 4 Scanner
|
FARO Version 3 Scanner
|
FARO Version 2 Scanner
|
Other Pages
- See VTube-LASER
- See FARO Version 6 Scanner
- See Surface Spray