Difference between revisions of "VTube Communication for UNISON Benders"
(→STEP 2: Setup the Benderlink Network Grid for UNISON Supravision Network Protocol) |
(→STEP 2: Setup the Benderlink Network Grid for UNISON Supravision Network Protocol) |
||
Line 70: | Line 70: | ||
#Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)<br><br> | #Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)<br><br> | ||
#If the UNISON rotates the Clockwise positive, then select YES in the CW Rotation Positive cell.<br><br> | #If the UNISON rotates the Clockwise positive, then select YES in the CW Rotation Positive cell.<br><br> | ||
− | #The "Ignore Incoming Linear Unit" setting is optional. This will not allow the UNISON to change the linear units in VTube-LASER if they are different. | + | #The "Ignore Incoming Linear Unit" setting is optional. This will not allow the UNISON to change the linear units in VTube-LASER if they are different.<br><br> |
#Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid. | #Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid. | ||
Revision as of 21:51, 11 February 2018
This page describes the use of the VTube to UNISON Supravision file communications. Descriptions for VTube-STEP and VTube-LASER are included. |
Protocol
VTube-STEP can send data directly to the UNISON LTD software YBC values. |
UNISON CONTROL SETUP
The connection uses a standard network connection between Windows computers. You will need to attach the UNISON bender to a standard network to allow this kind of communication.
You can share a folder on the UNISON with the VTube-LASER computer, or you can allow the UNISON control to gain access to a network location for READ/WRITE access.
Please ask UNISON technicians for assistance in making a connection.
BENDERLINK SETUP STEPS FOR VTUBE-STEP AND VTUBE-LASER
You can perform this setup from VTube-STEP or VTube-LASER. The steps are identical in both.
STEP 1: Enter the SYSTEM OPTIONS Menu in VTube
|
STEP 2: Setup the Benderlink Network Grid for UNISON Supravision Network Protocol
|
HOW TO SEND AND RECALL DATA FROM VTUBE-STEP AND VTUBE-LASER
How to SEND MASTER XYZ Data to the CRIPPA Control from VTube-STEP
You can import data or models into VTube-STEP then send the calculated LRA bender data to the CRIPPA bender using the VTube BENDER OUTPUT menu.
STEP 1 - Use the BENDER OUTPUT Menu
|
STEP 2 - SAVE the Data at the CRIPPA UII Software
CRIPPA will ask for confirmation to update when it receives the incoming data. Say "Yes". |
STEP 3 - SAVE and COMPILE
|
How to SEND MASTER LRA Data to the CRIPPA Control from VTube-LASER
You can also send the new LRA data from the VTube-LASER BENDER SETUP menu to the CRIPPA bender using the VTube Bender Output menu.
Press the "BENDER SETUP button in the Navigation Pane. |
STEP 2 - Choose the BENDER NUMBER
Set the correct bender number at the top of the window. |
STEP 3 - Setup the Bender Setup Data in this WINDOW
This is for first-time setup for a new part. Data in this window is separate from data in the main VTube-LASER window, so it is necessary to bring data into this window when performing first-time setup of a part. This ensures that the correct data is sent to the CRIPPA.
|
STEP 3 - Send data to the CRIPPA BENDER
|
STEP 4 - The Send to Bender Complete Window
A window indicating that data was sent should appear for a few seconds then disappear automatically. |
STEP 5 - SAVE the Data at the CRIPPA UII Software
Move to the CRIPPA control. CRIPPA will ask for confirmation to update when it receives the incoming data. Say "Yes". |
How to SEND CORRECTION Data to the CRIPPA Control from VTube-LASER
STEP 1 - Bend the Tube
Bend the tube in the CRIPPA. |
STEP 2 - Measure the tube with VTube-LASER
Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape. |
STEP 3 - Enter BENDER SETUP
Click on the BENDER SETUP button in the Navigation Pane. |
For dual screen systems, VTube-LASER will let you press the Switch Screens button in the upper right corner in order to move the Bender Setup window to the second screen like this: |
STEP 4 - Choose the BENDER NUMBER
Set the correct bender number at the top of the window. |
STEP 5 - RECALL CRIPPA YBC data
Be sure the that the Part Number value is the same as the part name in the CRIPPA control. The CRIPPA will not return data unless it recognizes the part number. |
STEP 6 - OPTIONAL STEP - You Can Manually Change the ADJUSTMENT Values
You can manually change the ADJUSTMENT values before sending corrections if you want to. Some users like to set the first and last Length adjustment to zero in order to keep the start position of the carriage in the same place - for when they have extra length on the ends. |
STEP 7 - Send the CORRECTION Values to the CRIPPA
Click on AUTO SEND. This will send the ORANGE columns to the CRIPPA bender.
|
STEP 8 - The SEND ADJUSTED Window
A window should appear for a few seconds indicating that the Send to the Bender is complete. |
STEP 9 - SAVE the New Data at the CRIPPA UII Software
Move to the CRIPPA control. CRIPPA will ask for confirmation to update when it receives the incoming data. Say "Yes". |
STEP 10 - REPEAT STEPS 1 THROUGH 9
Bend the tube in the CRIPPA (Step 1) then measure it again (Step 2) and follow the rest of the steps until the part is within tolerance. |
Other Pages
- See VTube-LASER
- See VTube-STEP
- See CRIPPA for information on CRIPPA benders