Difference between revisions of "VTube-LASER v2.9.3"
(→25pxNEW - MTA - MEASURED TUBE AVERAGING - SUPER ACCURATE MEASURES MADE EASY) |
(→Revision 2.9.3) |
||
(52 intermediate revisions by one user not shown) | |||
Line 6: | Line 6: | ||
==Revision 2.9.3== | ==Revision 2.9.3== | ||
− | Release Date: February | + | Release Date: February 4, 2018<br> |
+ | Build: 78 | ||
* Back to [[VTube-LASER]] | * Back to [[VTube-LASER]] | ||
* Back to [[VTube Software Updates|VTube-LASER Updates]] | * Back to [[VTube Software Updates|VTube-LASER Updates]] | ||
* See also [[VTube-STEP Updates]] | * See also [[VTube-STEP Updates]] | ||
− | * Download | + | * Download updates the [https://www.advancedtubularsupport.com Support Page] |
Line 21: | Line 22: | ||
</table> | </table> | ||
− | + | __TOC__ | |
− | ==[[image:Check.jpg|25px]]NEW - MTA | + | ==[[image:Check.jpg|25px]]NEW - MTA (MEASURED TUBE AVERAGING) - SUPER ACCURATE MEASURES MADE EASY== |
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
Line 29: | Line 30: | ||
<td width=300> | <td width=300> | ||
− | MEC Inc. (Mayville Engineering) performed several tests on large-diameter tubes to confirm that measuring both sides of the tube has a positive impact on the measurement of tube shapes. They | + | <font size=3>'''This feature was requested by MEC, Inc. after several weeks of tests on tube measuring large diameter tubes.<br><br> |
+ | So we added the super-easy-to-use MTA feature as of this version.'''<br><br> | ||
+ | |||
+ | *See Video 76 in [[VTube-LASER Videos]] to see MTA in action.<br><br> | ||
+ | *Read details about the feature here: [[VTube-LASER MTA (Measured Tube Averaging)]]<br><br> | ||
+ | </font> | ||
+ | |||
+ | MEC Inc. (Mayville Engineering), one of our customer-reference companies, performed several tests on large-diameter tubes to confirm that measuring both sides of the tube has a positive impact on the measurement of tube shapes. '''They requested that we make creating averaged (hybrid) tubes easier for their operators. We agreed that this is a great idea, so we developed the MTA feature to answer the need.'''<br><br> | ||
+ | |||
+ | The MTA feature allows operators measure the tube, rotate it, measure it again, rotate it, etc. - as many times as they want to. And it's super easy to do.<br><br> | ||
+ | |||
+ | Also, new buttons were added to the Tube Measure Control window to make using this feature very easy (see below).<br><br> | ||
+ | [[image:vtl_2.9.3_TubeMeasureControl.png|250px]]<br><br> | ||
− | |||
− | |||
− | |||
</td> | </td> | ||
<td> | <td> | ||
[[image:MTA Banner.png|500px]]<br><br> | [[image:MTA Banner.png|500px]]<br><br> | ||
+ | [[image:MECbanner.png|500px]]<br><br> | ||
[[image:MTAWindow.png|500px]]<br><br> | [[image:MTAWindow.png|500px]]<br><br> | ||
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ==[[image:Check.jpg|25px]]NEW - SEND ASSEMBLIES TO SOLIDWORKS== | ||
+ | |||
+ | <table cellpadding=10 width=800> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=300> | ||
+ | VTube-LASER can now send entire tube assemblies to SOLIDWORKS with one button press.<br><br> | ||
+ | |||
+ | [[image:vtube_sw_assembly_or_drawing.png|300px]] | ||
+ | |||
+ | <font size=3>*See Video 77 in [[VTube-LASER Videos]] to see assembly build to SOLIDWORKS in action.<br><br> | ||
+ | </font> | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:assemblies2solidworks.png|500px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ==[[image:Check.jpg|25px]]NEW - WAFIOS CORRECTIONS ADDED== | ||
+ | |||
+ | <table cellpadding=10 width=800> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=300> | ||
+ | [[image:wafios svnet banner.png|250px]]<br><br> | ||
+ | VTube-LASER can now communicate with WAFIOS benders using the WAFIOS SVNET protocol. | ||
+ | |||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:wafios bender setup.png|700px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
<br><br> | <br><br> | ||
Line 107: | Line 160: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]]NEW - DENGLER Bender Corrections Support | + | ==[[image:Check.jpg|25px]]NEW - DENGLER Bender Corrections Support Added== |
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
Line 126: | Line 179: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]]NEW - | + | ==[[image:Check.jpg|25px]]NEW - SUPPORT FOR MICROSCRIBE ARMS FROM REVWARE== |
<table cellpadding=10 width=900> | <table cellpadding=10 width=900> | ||
Line 144: | Line 197: | ||
<td> | <td> | ||
− | [[image:vtl screen with microscribe arm.png| | + | [[image:vtl screen with microscribe arm.png|400px]]<br><br> |
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ==[[image:Check.jpg|25px]]NEW - CHIYODA EX CHS File IMPORT ADDED== | ||
+ | |||
+ | <table cellpadding=10 width=800> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=300> | ||
+ | [[image:ChiyodaEXbender.png|300px]]<br><br> | ||
+ | VTube-STEP (which is part of VTube-LASER) can now import Chiyoda EX CHS files. The data imported is:<br><br> | ||
+ | #Part Number<br><br> | ||
+ | #Diameter<br><br> | ||
+ | #Wall Thickness<br><br> | ||
+ | #Cut Length<br><br> | ||
+ | #FPB bender data<br><br> | ||
+ | #Centerline Radii | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:vtl_2.9.3_chiyodaEX_import.png|500px]]<br><br> | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 172: | Line 249: | ||
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
<tr valign=top> | <tr valign=top> | ||
+ | * A new Advanced Tubular Support site is now available at [https://www.advancedtubularsupport.com advancedtubularsupport.com]<br><br> | ||
+ | * Windows paint and stay-on-top issues were addressed for the VTube-LASER window. For example, it was not possible to bring other windows with focus on top of VTube-LASER. This has been resolved.<br><br> | ||
+ | * The CHIYODA EX EXPORT feature now exports the DIAMETER and WALL thickness.<br><br> | ||
+ | * If the Separation Timer was set to 0 milliseconds, it could require so many resources from the CPU that VTube would either become sluggish or even freeze. This has been resolved by enforcing a minimum timer interval of 10 milliseconds.<br><br> | ||
+ | * In the process of fixing the Separation Timer, we were also able to make VTube-LASER more efficient - especially for operations like alignment that follow the use of the Separation Timer. | ||
<td width=500> | <td width=500> |
Latest revision as of 04:45, 5 February 2018
Revision 2.9.3Release Date: February 4, 2018
|
NEW - MTA (MEASURED TUBE AVERAGING) - SUPER ACCURATE MEASURES MADE EASY
This feature was requested by MEC, Inc. after several weeks of tests on tube measuring large diameter tubes.
MEC Inc. (Mayville Engineering), one of our customer-reference companies, performed several tests on large-diameter tubes to confirm that measuring both sides of the tube has a positive impact on the measurement of tube shapes. They requested that we make creating averaged (hybrid) tubes easier for their operators. We agreed that this is a great idea, so we developed the MTA feature to answer the need. The MTA feature allows operators measure the tube, rotate it, measure it again, rotate it, etc. - as many times as they want to. And it's super easy to do. Also, new buttons were added to the Tube Measure Control window to make using this feature very easy (see below).
|
NEW - SEND ASSEMBLIES TO SOLIDWORKS
VTube-LASER can now send entire tube assemblies to SOLIDWORKS with one button press. *See Video 77 in VTube-LASER Videos to see assembly build to SOLIDWORKS in action. |
NEW - WAFIOS CORRECTIONS ADDED
|
NEW - NUMALLIANCE CORRECTIONS ADDED
VTube-LASER now has an export option for NUMALLIANCE CSV files that is used to correct the NUMALLIANCE benders. |
NEW - REDESIGNED TUBE EXPORT MENU for QUICK EXPORT with NUMALLIANCE EXPORT ADDED
We redesigned the FILE menu for the MASTER, MEASURED, and MEASURED ALIGNED menus. Now it is referred to as EXPORT. |
NEW - Diameter Cut Plane - Maximum Cloud Radius ZERO Warning
VTube-LASER will take in only one point per laser stripe if the Maximum Cloud Radius value is accidentally zero to ZERO and the DCP is set to ACTIVE. |
NEW - DENGLER Bender Corrections Support Added
Dengler benders are known for bending long brake and fuel lines. |
NEW - SUPPORT FOR MICROSCRIBE ARMS FROM REVWARE
VTube-LASER now supports the MicroScribe arms using ball probes. |
NEW - CHIYODA EX CHS File IMPORT ADDED
|
NEW - GUIDE WINDOWS IN BENDER SETUP ADDED
We've put Guide Windows in the Bender Setup menu. They can stay open for as long you as you want - or close them anytime. They are less obtrusive than the dialogs that required the operator to press "OK" to continue. |
Other
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature