Difference between revisions of "VTube-LASER v2.9.2"
(→25pxFIXED and IMPROVED - Split Bend - Finding Surface Edges) |
(→25pxFIXED and IMPROVED - END TRIM) |
||
(12 intermediate revisions by one user not shown) | |||
Line 5: | Line 5: | ||
− | ==Revision 2.9.2 Build | + | ==Revision 2.9.2 Build 109== |
− | Release Date: December | + | Release Date: December 12, 2017<br> |
* Back to [[VTube-LASER]] | * Back to [[VTube-LASER]] | ||
Line 43: | Line 43: | ||
− | ==[[image:Check.jpg|25px]]FIXED and IMPROVED - Bend Profile== | + | ==[[image:Check.jpg|25px]]FIXED and IMPROVED - Bend Profile Calculations== |
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
Line 53: | Line 53: | ||
<td> | <td> | ||
− | [[image: | + | [[image:bendprofile.png|500px]]<br><br> |
− | [[image: | + | </td> |
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]]FIXED and IMPROVED - END TRIM - (Build 108)== | ||
+ | |||
+ | <table cellpadding=10 width=800> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=300> | ||
+ | A customer discovered a rare end trim condition that we were able to reproduce and fix. The issue occurred when end trim stripes were captured both near the end and near the first or last bend. This confused the end trim logic. The logic has been completely redesigned to not only overcome this issue - but to find the end-trim even faster than before.<br><br> | ||
+ | Our tests also showed that, with this new logic, the end-scan technique is not as important as it was in previous versions. The key is to be sure that the END WALL is the furthest point out in an end scan.<br><br> | ||
+ | See the image on the right for an example. Using this kind of scan - with lots of points along the diameter, we were able to consistently find the end of this tube within a few thousandths every time. | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:vtl_2.9.2_endtrim_from_scans_furthest.png|500px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ==[[image:Check.jpg|25px]]Other== | ||
+ | |||
+ | <table cellpadding=10 width=800> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=500> | ||
+ | * A bug was discovered for saving the Default Project file where some of values recently changed would not be stored in the default setup. '''This is fixed.'''<br><br> | ||
+ | * (Build 109) - The Bender Data Setup window bender number was always reset to 1 whenever the measured tube was created. This has been fixed so that the previously selected bender is remembered and displayed. | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 23:11, 12 December 2017
Revision 2.9.2 Build 109Release Date: December 12, 2017
|
FIXED and IMPROVED - Split Bend - Finding Surface Edges
As of version 2.9, the Split Bend logic would not find the exact outside of the apex of the surface diameters in 180-degree bends. |
FIXED and IMPROVED - Bend Profile Calculations
The same issues that affected the Split Bend logic also affected the Bend Profile logic. |
FIXED and IMPROVED - END TRIM - (Build 108)
A customer discovered a rare end trim condition that we were able to reproduce and fix. The issue occurred when end trim stripes were captured both near the end and near the first or last bend. This confused the end trim logic. The logic has been completely redesigned to not only overcome this issue - but to find the end-trim even faster than before. |
Other
|
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature