Difference between revisions of "VTube-LASER v2.8.5"

From ATTWiki
Jump to: navigation, search
(Revision 2.8.5)
(25px BUILD 2 - IMPROVED: REVERSE CALC)
Line 55: Line 55:
 
<br><br>
 
<br><br>
  
==[[image:Check.jpg|25px]] BUILD 2 - IMPROVED: REVERSE CALC==
+
==[[image:Check.jpg|25px]] BUILD 1 - IMPROVED: REMOVED "Move Arm from Cradle" MESSAGE==
  
 
<table cellpadding=10 width=900>
 
<table cellpadding=10 width=900>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
In previous versions, when performing REVERSE CALC from bender data to centerline XYZ data, VTube-LASER could not keep the previous part orientation in 3D space when the first leg ran parallel to the Z axis.<br><br>
+
This message appeared when loading VTube-LASER projects on older arms. This message is no longer displayed because it is not needed with then newer FARO drivers.
The part data on the right shows the first leg moving positive only in the Z axis. This is an example of data that could not be handled during reverse calculation.<br><br>
+
The math engine has been improved to handle this condition.
+
 
<td>
 
<td>
[[image:vtube-laser_2.9.4_reverse calc.png|400px]]
+
 
 
</td>
 
</td>
 
<td>
 
<td>

Revision as of 22:06, 26 July 2017

Vtube-laser logo 1.96.png


Revision 2.8.5

Original Release Date: July 26, 2017
Latest Build: 1


Vtube-laser v2.7 screenshot.png

Contents


Check.jpg BUILD 1 - NEW: IMPORT ONLY MASTER DATA FROM VTP FILES

You can now import the MASTER tube data from VTP - VTube Project files.

This allows for the import of older VTube-LASER project files without changing the measuring center setup for newer versions of VTube-LASER.

Vtube-laser v2.8.5 importVTPmaster.png


Check.jpg Build 1 - NEW: SEARCH AND MOVE IN PATH MANAGER

VTube now lets you search for path names in the Path Manager.

It also allows you to move the paths up or down in the lost.

Vtube-step 2.8.4 pathmanager search.png



Check.jpg BUILD 1 - IMPROVED: REMOVED "Move Arm from Cradle" MESSAGE

This message appeared when loading VTube-LASER projects on older arms. This message is no longer displayed because it is not needed with then newer FARO drivers.

Check.jpg BUILD 2 - NEW: DATUM REPORT TEMPLATES - MEASURED Distances to MASTER DATUM

Previous versions of VTube could only display DATUM reports with MEASURED-ALIGNED to MEASURED-ALIGNED DATUM or MASTER to MASTER DATUM values.

Now VTube-LASER can show DATUM reports with MEASURED-ALIGNED distances to MASTER Datums.



To use these new report templates:

  1. Download these two new templates: Zip file of Measured to Master Datum Report Templates.
  2. Extract them to a folder location that you can find.
  3. Load VTube-LASER.
  4. Go to Reports.
  5. Click on the Templates tab.
  6. Click on Import.
  7. Find and click on the new Datum templates.
  8. Repeat at step 5 for the second template file.

Vtube-laser 2.8.4 datum report.png

Check.jpg BUILD 2 - IMPROVED: REPORT WINDOW TO FRONT

We've improved the REPORT window's ability to come to the top of the current window.

Vtube-laser v2.8.4 report on top.png


Check.jpg BUILD 3 - NEW: GERMAN TRANSLATION UPDATED

The German translation for VTube-LASER is updated and included in the installation.

The translation is in the file german_v2.8.4_build3.xls.


Check.jpg BUILD 3 - NEW: JAPANESE TRANSLATION UPDATED

The Japanese translation for VTube-LASER is updated and included in the installation.

The translation is in the file japanese_v2.8.4_build3.xls.


Check.jpg BUILD 3 - NEW: FRENCH TRANSLATION UPDATED

The French translation for VTube-LASER is updated and included in the installation.

The translation is in the file french_v2.8.4_build3.xls.

Check.jpg BUILD 3 - FIX: USER INTERFACE ENGLISH GRAMMAR CORRECTIONS

Our German translator helped us correct several problems with the English in the VTube user interface.

Other Pages