Difference between revisions of "VTube-STEP v2.3"
(→25px NEW: Press Enter to Set Point Count) |
(→25px ENHANCED: Increase Maximum Point Limit from 102 up to 202 (200 Bends)) |
||
Line 67: | Line 67: | ||
<td width=300> | <td width=300> | ||
One customer had parts that required over 100 bends, so we increased the maximum number of bends allowed in VTube to 200.<br><br> | One customer had parts that required over 100 bends, so we increased the maximum number of bends allowed in VTube to 200.<br><br> | ||
− | + | Note: For drawing models with more than 100 bends we strongly recommend an engineering-workstation level computer. Use the most powerful computer you can when the bend count is high.<br><br> | |
<br><br> | <br><br> | ||
Revision as of 00:06, 12 February 2016
Revision 2.3
|
- See VTube-STEP Customer Support Page to download the latest version.
This Update is Important For...
- Customers that use springback compensation of any form in VTube
- Customers that use tube elongation percentage to predict cut length and unbending lengths
- Customers that experienced image draw problems in the REPORT window
FIX: Tube Image Display and Refresh in the Report Window
|
NEW: Press Enter to Set Point Count
Users like to press the Enter key after entering the point count in the XYZ grids, so we've allowed for that action VTube. |
ENHANCED: Increase Maximum Point Limit from 102 up to 202 (200 Bends)
One customer had parts that required over 100 bends, so we increased the maximum number of bends allowed in VTube to 200. |
ENHANCEMENT: Blank White Cells Replace Dashes and Zeros
The grid interface is now cleaner than in previous versions. Previous versions would show zeros for the end point radii, and also dashes in LRA cells that are not used. |
FIX: Springback Compensation Issues Repaired
If you use springback compensation in VTube, then this upgrade is important for you. |
NEW: Springback-Compensated LRA Grids
NEW: Multi-Elongation Percentage Compensation Setup
ENHANCEMENT: Springback Compensation Calculation in the Outgoing Bender Data Is Now Optional
This feature adds springback compensation into the outgoing LRA data. In previous versions it was not optional. For some benders (for example, the Eaton Leonard Lightspeed) this addition is NOT recommended because this causes the springback to be added by both VTube and the bender. This doubles the compensation - which is incorrect. If you're not sure if you should use this option, then test how your bender uses the springback compensation values by entering non-zero Springback values in VTube's Part Setup menu, then send data with this feature activated. If the bend values display with the overbend doubled, then you know that the control handles the springback compensation automatically. |
ENHANCEMENT: Keep the Previous Custom Default Setup During Upgrades
If you've made changes to your default settings, you will want to skip installing a new set of configuration files. This version allows you to skip the installation of new configuration files with new choices in the installation file. In addition to updating the main program files, you can now also control installation of:
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER