Difference between revisions of "Recommended VTube-LASER Laser Scanner Settings"
From ATTWiki
(→Ideal Setup for the HD (Version 6) Blue Laser Scanner in VTube-LASER) |
(→Ideal Setup for the HD (Version 6) Blue Laser Scanner in VTube-LASER) |
||
Line 22: | Line 22: | ||
<td width=300> | <td width=300> | ||
The FARO ScanArm HD blue laser scanner has significantly increased capabilities compared to earlier FARO scanners.<br><br> | The FARO ScanArm HD blue laser scanner has significantly increased capabilities compared to earlier FARO scanners.<br><br> | ||
− | Because of that, it requires different setup recommendations for the FARO Laser Line Probe Control window. These settings work very well in VTube-LASER specifically with the HD scanner.<br><br> | + | Because of that, it requires different setup recommendations for the FARO Laser Line Probe Control window. These settings work very well in VTube-LASER ''specifically'' with the HD scanner.<br><br> |
'''VTube-LASER be connected to a FARO arm to perform these steps.''' | '''VTube-LASER be connected to a FARO arm to perform these steps.''' | ||
</td> | </td> |
Revision as of 03:14, 26 December 2015
|
Page Revision Date: December 24, 2015
Ideal Setup for the HD (Version 6) Blue Laser Scanner in VTube-LASER
The FARO ScanArm HD blue laser scanner has significantly increased capabilities compared to earlier FARO scanners. |
STEP 1In VTube-LASER window click on Scanner Algorithm label above the viewport window. |
|
STEP 2Set the Scan Rate to 1/1.
Set the Scan Density to 1/16
|
|
STEP 3For most materials set the Algorithm to Automatic - Normal. |
|
STEP 4Uncheck the Reflection Filter option.
|
|
STEP 5Click on the OK button to exit the FARO Laser Line Probe window. |
Other Pages
- Back to the VTube-LASER page