Difference between revisions of "Revision: Benderlink for BLM 5.3"

From ATTWiki
Jump to: navigation, search
(25px NEW - Click on LEDs to Toggle to Measuring Center Monitoring)
 
(27 intermediate revisions by one user not shown)
Line 9: Line 9:
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:blinkblm_v5_screen.jpg|250px]]
+
[[image:benderlinkblm_v5.3_screen.png|250px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 20: Line 20:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] ENHANCED - The LASERVISION Protocol is Enhanced===
+
 
 +
===[[image:Check.jpg|25px]] NEW - Communications Transfers No Longer Change the BLM Radius Levels===
 
<table width=700>
 
<table width=700>
  
 
<tr>
 
<tr>
 
<td width=300>
 
<td width=300>
The Laservision protocol will now work properly with Windows versions of LASERVISION<br><br>
+
Setting or changing BLM radius levels could easily cause radius level mix ups during corrections loops.  The radius levels are no longer touched or changed during transfer.  <br><br>
 +
Not setting the radius levels is no problem - since corrections loops targets the LRA data only anyway.
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:vector_tube_data_center.jpg|400px]]<br>
+
[[image:blinkblm_electric_verticalshift.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 35: Line 37:
 
<br><br>
 
<br><br>
  
 +
===[[image:Check.jpg|25px]] NEW - Switch for "Do Not Allow Measuring Center to Change End Lengths"===
 +
<table width=700>
  
 +
<tr>
 +
<td width=300>
 +
During CORRECTION of parts with extra material on the ends, it is helpful to not allow the end lengths to change.  This keeps the carriage in approximately the same start position even after corrections are applied.<br><br>
 +
This version of Benderlink now includes this checkbox switch to turn this feature on or off.
 +
</td>
 +
<td width=400>
 +
[[image:blinkblm_donotallowmeasuringcenterchangeendlengths.png|400px]]
 +
</td>
 +
</tr>
 +
 +
</table>
 +
<br><br>
  
===[[image:Check.jpg|25px]] NEW - Click on LED to Open Port to Measuring Center===
+
===[[image:Check.jpg|25px]] ENHANCED - The Communications Protocol is Enhanced for LASERVISION Windows Version===
 
<table width=700>
 
<table width=700>
  
 
<tr>
 
<tr>
 
<td width=300>
 
<td width=300>
You can now click on the LED port indicator to open a connection to the measuring center.<br><br>
+
The internal communications logic was enhanced to work properly with Windows versions of LASERVISION.  (It already worked with DOS versions of LASERVISION.)<br><br>
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:blinkblm_clickon_led_toggle.png|400px]]
+
[[image:vector_tube_data_center.jpg|400px]]<br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 53: Line 69:
  
  
===[[image:Check.jpg|25px]] FIXED - Ping Port Confirmation Works in Newer Windows===
+
===[[image:Check.jpg|25px]] NEW - Large Green LED to Show Measuring Center Monitoring===
 +
<table width=700>
 +
 
 +
<tr>
 +
<td width=300>
 +
A new larger green LED port indicator to show that Benderlink is monitoring for measuring center communications is added to the interface.<br><br>
 +
It is also possible to click on the LED to toggle the measuring center monitor state.
 +
</td>
 +
<td width=400>
 +
[[image:benderlinkblm_v5.3_large_led.png|400px]]
 +
</td>
 +
</tr>
 +
 
 +
</table>
 +
<br><br>
 +
 
 +
 
 +
===[[image:Check.jpg|25px]] NEW - Click on LEDs to Toggle to Measuring Center Monitoring===
 +
<table width=700>
 +
 
 +
<tr>
 +
<td width=300>
 +
You can now click on either LED indicator to toggle monitoring for the measuring center commmands.<br><br>
 +
</td>
 +
<td width=400>
 +
[[image:benderlinkblm_v5.3_both_leds.png|400px]]
 +
</td>
 +
</tr>
 +
 
 +
</table>
 +
<br><br>
 +
 
 +
===[[image:Check.jpg|25px]] FIXED - Ping Port Confirmation Works in Windows 7, 8, 8.1, 10===
 
<table width=700>
 
<table width=700>
  
Line 69: Line 117:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] NEW - Message Warning for Ports That Cannot Open===
+
===[[image:Check.jpg|25px]] NEW - Message Warning for COM Ports That Cannot Open===
 
<table width=700>
 
<table width=700>
  
 
<tr>
 
<tr>
 
<td width=300>
 
<td width=300>
When a port to the measuring center cannot open, Benderlink now displays a message that a problem occurred.
+
When a COM port to the measuring center cannot open, Benderlink now displays a message that a problem occurred.
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>

Latest revision as of 22:03, 14 October 2015

Benderlink blm logo.jpg

Revision 5.3

Benderlinkblm v5.3 screen.png






Check.jpg NEW - Communications Transfers No Longer Change the BLM Radius Levels

Setting or changing BLM radius levels could easily cause radius level mix ups during corrections loops. The radius levels are no longer touched or changed during transfer.

Not setting the radius levels is no problem - since corrections loops targets the LRA data only anyway.

Blinkblm electric verticalshift.png



Check.jpg NEW - Switch for "Do Not Allow Measuring Center to Change End Lengths"

During CORRECTION of parts with extra material on the ends, it is helpful to not allow the end lengths to change. This keeps the carriage in approximately the same start position even after corrections are applied.

This version of Benderlink now includes this checkbox switch to turn this feature on or off.

Blinkblm donotallowmeasuringcenterchangeendlengths.png



Check.jpg ENHANCED - The Communications Protocol is Enhanced for LASERVISION Windows Version

The internal communications logic was enhanced to work properly with Windows versions of LASERVISION. (It already worked with DOS versions of LASERVISION.)

Vector tube data center.jpg




Check.jpg NEW - Large Green LED to Show Measuring Center Monitoring

A new larger green LED port indicator to show that Benderlink is monitoring for measuring center communications is added to the interface.

It is also possible to click on the LED to toggle the measuring center monitor state.

Benderlinkblm v5.3 large led.png




Check.jpg NEW - Click on LEDs to Toggle to Measuring Center Monitoring

You can now click on either LED indicator to toggle monitoring for the measuring center commmands.

Benderlinkblm v5.3 both leds.png



Check.jpg FIXED - Ping Port Confirmation Works in Windows 7, 8, 8.1, 10

This feature allows Benderlink to ping for a serial device server before opening a virtual port.

The feature worked in older Windows - but did not work in Windows 7 and higher. Now it works in the newer Windows versions too.

Blinkblm pingportconfirmation.png



Check.jpg NEW - Message Warning for COM Ports That Cannot Open

When a COM port to the measuring center cannot open, Benderlink now displays a message that a problem occurred.

400



Other Pages