Difference between revisions of "VTube Communication with YLM Benders"
From ATTWiki
(→Follow these steps to import the measured data from VTube-LASER) |
(→VTube-LASER Correction Steps for YLM Benders) |
||
Line 39: | Line 39: | ||
==[[VTube-LASER]] Correction Steps for YLM Benders== | ==[[VTube-LASER]] Correction Steps for YLM Benders== | ||
+ | |||
+ | ===Follow these steps at VTube-LASER to Correct a YLM Bender=== | ||
<table> | <table> | ||
<tr valign=top> | <tr valign=top> | ||
Line 47: | Line 49: | ||
* First, for a CORRECTION, the YLM takes in VTube MEASURED Supravision LRA data. To make a correction to a YLM bender, it is important to send ONLY this data. The standard correction process will not work with the YLM.<br><br> | * First, for a CORRECTION, the YLM takes in VTube MEASURED Supravision LRA data. To make a correction to a YLM bender, it is important to send ONLY this data. The standard correction process will not work with the YLM.<br><br> | ||
* Second, the YLM sends the correction the wrong way when taking in the MEASURED data and comparing it to its MASTER or NOMINAL data. The only way overcome this is to use a special INVERSION checkbox in the Supravision Export menu. Only use this inversion switch when sending measured data for correction.<br><br> | * Second, the YLM sends the correction the wrong way when taking in the MEASURED data and comparing it to its MASTER or NOMINAL data. The only way overcome this is to use a special INVERSION checkbox in the Supravision Export menu. Only use this inversion switch when sending measured data for correction.<br><br> | ||
+ | |||
+ | </td> | ||
+ | <td width=400> | ||
+ | [[image:VTube-Laser-SaveMeasuredTubeData.jpg|500px]]<br><br> | ||
+ | [[image:vtube-laser-1.96_SupravisionExportMenu.png|500px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
===Follow these steps at the YLM CONTROL to import the measured data from VTube-LASER=== | ===Follow these steps at the YLM CONTROL to import the measured data from VTube-LASER=== | ||
+ | |||
+ | <table> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
* In the YLM YBC menu, click on CORRECTION. | * In the YLM YBC menu, click on CORRECTION. | ||
* Select the $$$ file that was created by VTube-LASER. | * Select the $$$ file that was created by VTube-LASER. | ||
Line 55: | Line 70: | ||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | |||
− | |||
[[image:YLM_Import_Screen.jpg|500px]]<br> | [[image:YLM_Import_Screen.jpg|500px]]<br> | ||
</td> | </td> |
Revision as of 01:39, 24 September 2014
|
Contents |
YLM Control software
The YLM Windows software allows for complete programming of bender setup. It includes a bender simulator. |
VTube-STEP and VTube-LASER Support for YLM Benders
VTube-STEP can export Supravision data to YLM benders. |
VTube-LASER Correction Steps for YLM Benders
Follow these steps at VTube-LASER to Correct a YLM Bender
The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer.
|
Follow these steps at the YLM CONTROL to import the measured data from VTube-LASER
|
Other Pages
- See VTube-LASER
- See VTube-STEP