Difference between revisions of "CNC Bender v12.11"
(→25px ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear) |
(→25px NEW: New PostBend Option - Release Shift Away) |
||
(One intermediate revision by one user not shown) | |||
Line 27: | Line 27: | ||
* It works in all other modes. | * It works in all other modes. | ||
<td> | <td> | ||
− | [[image:cnc_v12.11_postbend_releaseshiftaway.png| | + | [[image:cnc_v12.11_postbend_releaseshiftaway.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 33: | Line 33: | ||
<br><br> | <br><br> | ||
− | |||
==[[image:Check.jpg|25px]] ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear== | ==[[image:Check.jpg|25px]] ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear== |
Latest revision as of 20:37, 16 July 2014
v12.11 - July 16, 2014
|
NEW: New PostBend Option - Release Shift Away
A PostBend Release Shift Away option is added that allows the process to shift the tube out of the dies just after the dies open in the RELEASE section of the process.
|
ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear
Previous versions of CNC Bender would clear the Tool page when the Tube Shape page was cleared. This creates a problem in workflow, because the tool data is setup before the part is setup. Clearing the TubeShape page should never clear the tool page. |
FIX: Custom Command Editor
The Custom Commands menu and Custom Command Editor would sometimes show an error when clearing the menu then re-entering the Editor. |
ENHANCED: CNC Program Loader Allows for Adjustable CNC Executable Location
The location of the CNC Bender executable files can change depending on the application. The Program Loader can now run the CNC Bender program from any location - not just the standard "C:\CNC" folder location. |
Other Changes
|
Other Pages
- Back to CNC Bender
- Back to CNC Bender Software Updates
- See CNC Bender Customer Service Page for an update.
- See CNC Bender General Information
- See Teach Mode
- See Custom Commands