Difference between revisions of "CNC Bender v12.11"
(→25px FIX: Custom Command Editor) |
(→25px NEW: New PostBend Option - Release Shift Away) |
||
(4 intermediate revisions by one user not shown) | |||
Line 15: | Line 15: | ||
__NOTOC__ | __NOTOC__ | ||
+ | |||
+ | ==[[image:Check.jpg|25px]] NEW: New PostBend Option - Release Shift Away== | ||
+ | |||
+ | <table> | ||
+ | <tr> | ||
+ | <td width=300> | ||
+ | |||
+ | A PostBend Release Shift Away option is added that allows the process to shift the tube out of the dies just after the dies open in the RELEASE section of the process.<br><br> | ||
+ | * This option has no effect in any release mode that involves a robot. | ||
+ | * This option has no effect in the Custom Release mode. | ||
+ | * It works in all other modes. | ||
+ | <td> | ||
+ | [[image:cnc_v12.11_postbend_releaseshiftaway.png|500px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
==[[image:Check.jpg|25px]] ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear== | ==[[image:Check.jpg|25px]] ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear== | ||
Line 30: | Line 48: | ||
</table> | </table> | ||
− | |||
<br><br> | <br><br> | ||
Line 70: | Line 87: | ||
<tr> | <tr> | ||
<td width=400> | <td width=400> | ||
− | * | + | * Removed the second scroll bar on the right side of the File Load menu since it was redundant. |
</td> | </td> | ||
Line 79: | Line 96: | ||
<br><br> | <br><br> | ||
− | |||
==Other Pages== | ==Other Pages== |
Latest revision as of 20:37, 16 July 2014
v12.11 - July 16, 2014
|
NEW: New PostBend Option - Release Shift Away
A PostBend Release Shift Away option is added that allows the process to shift the tube out of the dies just after the dies open in the RELEASE section of the process.
|
ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear
Previous versions of CNC Bender would clear the Tool page when the Tube Shape page was cleared. This creates a problem in workflow, because the tool data is setup before the part is setup. Clearing the TubeShape page should never clear the tool page. |
FIX: Custom Command Editor
The Custom Commands menu and Custom Command Editor would sometimes show an error when clearing the menu then re-entering the Editor. |
ENHANCED: CNC Program Loader Allows for Adjustable CNC Executable Location
The location of the CNC Bender executable files can change depending on the application. The Program Loader can now run the CNC Bender program from any location - not just the standard "C:\CNC" folder location. |
Other Changes
|