Difference between revisions of "VTube-LASER v1.81.6"

From ATTWiki
Jump to: navigation, search
(25px Other Changes)
 
(11 intermediate revisions by one user not shown)
Line 3: Line 3:
 
<td width=225>
 
<td width=225>
 
[[image:vtube-laser_logo.jpg|300px]]
 
[[image:vtube-laser_logo.jpg|300px]]
==Revision 1.82==
+
==Revision 1.81.6==
 
* Back to [[VTube-STEP]]
 
* Back to [[VTube-STEP]]
 
* Back to [[VTube Software Updates]] (for LASER Mode)
 
* Back to [[VTube Software Updates]] (for LASER Mode)
Line 26: Line 26:
 
<td width=400>
 
<td width=400>
  
We've changed the interface to move the FARO arm utilities into a single window.  The Arm Utilities button in the Measure Setup / Arm tab menu loads this window.
+
* We've changed the interface to move the FARO arm utilities into a single window.  The Arm Utilities button in the Measure Setup / Arm tab menu loads this window.<br><br>
 
   
 
   
 
[[image:vtube-laser-1.82_armutilitieswindow.jpg|400px]]
 
[[image:vtube-laser-1.82_armutilitieswindow.jpg|400px]]
  
When the window loads, the window takes over the connection the arm and allows you to perform probe setup, calibration, diagnostics, single point accuracy tests, etc.
+
* When the window loads, the window takes over the connection the arm and allows you to perform probe setup, calibration, diagnostics, single point accuracy tests, etc.<br><br>
  
 +
* This fixes a problem where the LLP calibration would not always exit properly.
  
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
 
[[image:vtube-laser-1.82_lasertabmenu_circle_armutilities.jpg|300px]]<br>
 
[[image:vtube-laser-1.82_lasertabmenu_circle_armutilities.jpg|300px]]<br>
 +
</td>
 +
</tr>
 +
</table>
 +
 +
<br><br>
 +
 +
===[[image:Check.jpg|25px]] ENHANCED - New Popup in Part Setup for Overbend and Cut Length Calculators===
 +
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=400>
 +
[[image:vtube-1.81.6-partsetup_popup_laser.jpg|400px]]<br>
 +
* This change gives more room to the grid of values to display on the screen without scrolling by removing the two buttons from the bottom of the Part Setup menu.<br><br>
 +
</td>
 +
<td width=300>
 +
[[image:vtube-1.81.6-partsetup_laser.jpg|300px]]<br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 47: Line 64:
 
<td width=400>
 
<td width=400>
 
   
 
   
* The Connect to Arm feature has been rewritten to make it more robust.  It is also now possible to disconnect from the FARO arm at any time using the "Disconnect from Arm" button.
+
* The Connect to Arm feature has been rewritten to make it more robust.  It is also now possible to disconnect from the FARO arm at any time using the "Disconnect from Arm" button.<br><br>
 +
* Overbend Calculator is now integrated into VTube.  The values are now always updated and transferred back to VTube as they are entered in the Overbend.<br><br>
 +
* Supravision export in STEP mode would send an incorrect wall thickness value.  This has been resolved.<br><br>
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Latest revision as of 20:11, 12 June 2013

Vtube-laser logo.jpg

Revision 1.81.6

Vtube-laser 1.81.4.jpg





Check.jpg NEW: FARO Arm Utilities Window

  • We've changed the interface to move the FARO arm utilities into a single window. The Arm Utilities button in the Measure Setup / Arm tab menu loads this window.

Vtube-laser-1.82 armutilitieswindow.jpg

  • When the window loads, the window takes over the connection the arm and allows you to perform probe setup, calibration, diagnostics, single point accuracy tests, etc.

  • This fixes a problem where the LLP calibration would not always exit properly.

Vtube-laser-1.82 lasertabmenu circle armutilities.jpg



Check.jpg ENHANCED - New Popup in Part Setup for Overbend and Cut Length Calculators

Vtube-1.81.6-partsetup popup laser.jpg

  • This change gives more room to the grid of values to display on the screen without scrolling by removing the two buttons from the bottom of the Part Setup menu.

Vtube-1.81.6-partsetup laser.jpg



Check.jpg Other Changes

  • The Connect to Arm feature has been rewritten to make it more robust. It is also now possible to disconnect from the FARO arm at any time using the "Disconnect from Arm" button.

  • Overbend Calculator is now integrated into VTube. The values are now always updated and transferred back to VTube as they are entered in the Overbend.

  • Supravision export in STEP mode would send an incorrect wall thickness value. This has been resolved.

Vtube-laser-1.82 lasertabmenu disconnectfromarm.jpg

Other