Difference between revisions of "VTube-LASER v1.77.4"
Line 65: | Line 65: | ||
The new logic allows for this behavior: As the deviations between MASTER and MEASURED data shrink - so do the number of iterations that VTube will take to align the measured tube. Tube shapes that are well within tolerance will align faster with Automatic End Weighting than tubes that are out of tolerance.<br><br> | The new logic allows for this behavior: As the deviations between MASTER and MEASURED data shrink - so do the number of iterations that VTube will take to align the measured tube. Tube shapes that are well within tolerance will align faster with Automatic End Weighting than tubes that are out of tolerance.<br><br> | ||
+ | |||
+ | Also, the new logic will give priority to an orientation with | ||
The algorithm now finds the orientations with the least number of total tangent points out of tolerance before examining the deviation averages. This extra FIRST step removes orientations that may have a lower average deviation - but a higher number of out-of-tolerance tangent points. This step is critical because the goal in this kind of alignment is to find the orientation with the fewest centerline tangent points out of tolerance.<br><br> | The algorithm now finds the orientations with the least number of total tangent points out of tolerance before examining the deviation averages. This extra FIRST step removes orientations that may have a lower average deviation - but a higher number of out-of-tolerance tangent points. This step is critical because the goal in this kind of alignment is to find the orientation with the fewest centerline tangent points out of tolerance.<br><br> |
Revision as of 02:48, 15 August 2012
Revision 1.77.4
|
NEW: Pulldown Menus
|
NEW: Recent Project List in the Pulldown Menus
Recent Projects can be reloaded with one click from the File pulldown menu. |
NEW: Real "Save" Command Distinct from "Save As..."
VTube now allows you to save the current project without having to supply the current filename again. Hit the blue disk, and VTube will save the data without any interruption. |
ENHANCED: Best Fit - Automatic Weighting Algorithm Logic Redesigned
The Best Fit Automatic Weighting alignment type logic was redesigned to follow better logic for finding the best end-weights automatically. The new logic allows for this behavior: As the deviations between MASTER and MEASURED data shrink - so do the number of iterations that VTube will take to align the measured tube. Tube shapes that are well within tolerance will align faster with Automatic End Weighting than tubes that are out of tolerance. Also, the new logic will give priority to an orientation with The algorithm now finds the orientations with the least number of total tangent points out of tolerance before examining the deviation averages. This extra FIRST step removes orientations that may have a lower average deviation - but a higher number of out-of-tolerance tangent points. This step is critical because the goal in this kind of alignment is to find the orientation with the fewest centerline tangent points out of tolerance. |
NEW: Best Fit - Deviation to Tolerance Ratio
ENHANCED: Better Feed Back Progress during Best Fit - Automatic Weighting
NEW: Hardware Key Information Window
The new hardware key window will show the details of your license found in the hardware key that enables VTube to run. The command to display the window is inside the new Help pulldown menu. |
NEW: Close VTube from LASER Mode
You can now close VTube from the LASER mode. |
NEW: Low Level User Interface Value: Maximum Recent Files
Use this to control how many files display in the Recent Project list in the pulldown menu. The default is 10 files. |
ENHANCED: Allow the Drawing of ZERO Value Radii
VTube can now draw a zero-radius bend in the model with displaying an error. |
Other Pages
- Back to the VTube-LASER page