− | * Align the scanner at the end wall of the tube. | + | * Align the scanner at the end wall of the tube.<br><br> |
− | * | + | * Be careful to not allow the laser reflection to strike you in the eyes.<br><br> |
− | + | ||
* Attempt to hold the laser motionless when collecting the stripes across the end to increase repeatability.<br><br> | * Attempt to hold the laser motionless when collecting the stripes across the end to increase repeatability.<br><br> | ||
* Consistently place the line across the same area of the tube end from measure to measure.<br><br> | * Consistently place the line across the same area of the tube end from measure to measure.<br><br> |
Revision as of 03:45, 1 February 2012
How to perform the end-wall end scan.
|
Why the End-Scan technique is important
This end-scan method is useful for increase in precision over the scissor method.
|
Measure Setup
|
How To Use This End-Scan Technique
The advantage of this method is that it is easy to use. The disadvantage is that it is more prone to outlier points from the inner diameter surface. |
Another Way to Use This End-Scan Technique
The advantage of this method is that it is less prone to outlier points. The disadvantage is that it is hard to aim at thinner walls. |