Difference between revisions of "VTube-LASER v1.6"
(28 intermediate revisions by one user not shown) | |||
Line 16: | Line 16: | ||
===[[image:Check.jpg|25px]] NEW: End Scan Outlier Detection=== | ===[[image:Check.jpg|25px]] NEW: End Scan Outlier Detection=== | ||
+ | [[image:vtube-laser_endscan_outlier_example.jpg|600px]]<br><br> | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
Line 29: | Line 30: | ||
<td width=300> | <td width=300> | ||
[[image:vtube-laser_endscan_outlier_detection.jpg|300px]]<br><br> | [[image:vtube-laser_endscan_outlier_detection.jpg|300px]]<br><br> | ||
+ | |||
</td> | </td> | ||
Line 40: | Line 42: | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
− | <td width= | + | <td width=300> |
The new grid interface in in Measure Setup has more options.<br><br> | The new grid interface in in Measure Setup has more options.<br><br> | ||
Line 47: | Line 49: | ||
*'''Continuous Scan on Tactile End-Scans''': Scan points repeatedly whenever you press the green button.<br><br> | *'''Continuous Scan on Tactile End-Scans''': Scan points repeatedly whenever you press the green button.<br><br> | ||
*'''Automatic display of Master model''': Show the master model with the current straight highlighted orange during measure.<br><br> | *'''Automatic display of Master model''': Show the master model with the current straight highlighted orange during measure.<br><br> | ||
− | + | [[image:vtube-laser_measuresetup_displayofmastermodel.jpg|300px]]<br> | |
</td> | </td> | ||
<td width=400> | <td width=400> | ||
[[image:vtube-laser_measuresetup_grid.jpg|400px]]<br> | [[image:vtube-laser_measuresetup_grid.jpg|400px]]<br> | ||
− | [[image:vtube- | + | |
+ | <br> | ||
+ | This is an image from continuous ball probe scanning:<br> | ||
+ | [[image:vtube-laser_continuous_tactile.jpg|400px]]<br> | ||
+ | |||
</td> | </td> | ||
</tr> | </tr> | ||
Line 57: | Line 63: | ||
<br><br> | <br><br> | ||
− | |||
===[[image:Check.jpg|25px]] ENHANCED: New Options in Part Setup=== | ===[[image:Check.jpg|25px]] ENHANCED: New Options in Part Setup=== | ||
Line 63: | Line 68: | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
− | <td width= | + | <td width=300> |
New '''A-End Diameter''' and '''B-End Diameter''' is added to the Part Setup menu.<br><br> | New '''A-End Diameter''' and '''B-End Diameter''' is added to the Part Setup menu.<br><br> | ||
− | The new diameters are used to qualify end-scans within the tolerance in System Options.<br><br> | + | The new diameters are used to qualify end-scans within the tolerance that is set in System Options (defaults to 1 mm).<br><br> |
− | [[image:vtube-laser_endscan_diameter_qualification_tolerance.jpg]] | + | [[image:vtube-laser_endscan_diameter_qualification_tolerance.jpg|300px]] |
+ | <br><br> | ||
+ | If either diameter is ZERO at measure time, then it will be reset to the current diameter value. This prevents a false rejection of good end-scan data. | ||
</td> | </td> | ||
+ | |||
<td width=400> | <td width=400> | ||
[[image:vtube-laser_partsetup_grid_1_6.jpg|400px]]<br> | [[image:vtube-laser_partsetup_grid_1_6.jpg|400px]]<br> | ||
Line 76: | Line 84: | ||
<br><br> | <br><br> | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] Other Changes === |
<table> | <table> | ||
<tr> | <tr> | ||
− | <td width= | + | <td width=300> |
− | + | * Better math handling when the radius is set to zero.<br><br> | |
− | <br><br | + | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | <br><br> | + | * Much more efficient redraws in the view port<br><br> |
+ | * Small user interface fixes and refinements<br><br> | ||
− | + | * The maximum number of LLP strings per measure allowed is increased in the Measure 2 tab of the Systems Options menu.<br><br> | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | <br><br | + | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | <br><br> | + | * The '''Measure a Tube''' control is changed to allow you to qualify the image on the screen before exiting the measure process. This adds a step to the measure process.<br><br> |
− | + | * Include '''End A Diameter''' and '''End B Diameter''' variables in Supravision file import and export.<br><br> | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | * New help file and manual with updates and additional sections like "How to Scan a Straight." | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | * | + | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
<td> | <td> | ||
+ | [[image:vtube-laser_finish_apply_measure_1_6.jpg|300px]]<br> | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 155: | Line 112: | ||
<br><br> | <br><br> | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] Issues with this version fixed in next version=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | * | + | * The Apply to Nominal Diameter button in the Diameter Measure control did not properly transfer diameter data to the Part Setup menu.<br><br> |
− | + | ||
− | + | ||
− | + | ||
− | < | + | |
− | <br><br> | + | * The Apply to Nominal Radius button in the Radius Measure control did not properly transfer radius data to the Part Setup menu.<br><br> |
− | + | * The End B diameter was overwritten by the End A diameter when the End A diameter changed.<br><br> | |
− | < | + | * The End A and End B diameter of zero would stop a reverse-engineering of the end without a diameter entered. This has been resolved with the automatic set End Diameter feature in the next version.<br><br> |
− | < | + | |
− | + | </td> | |
− | + | ||
<td width=300> | <td width=300> | ||
</td> | </td> |
Latest revision as of 21:50, 4 March 2011
Revision 1.6Back to VTube-LASER |
NEW: End Scan Outlier Detection
The end scan procedures in VTube-LASER are now enhanced to detect and remove outlier points in an end-scan. |
|
ENHANCED: New Features and Interface in Measure Setup
The new grid interface in in Measure Setup has more options. New options include:
|
ENHANCED: New Options in Part Setup
Other Changes
|
Issues with this version fixed in next version
|
Other Pages
- Back to VTube-LASER