Difference between revisions of "YLM"

From ATTWiki
Jump to: navigation, search
(VTube-STEP and VTube-LASER Support for YLM Benders)
Line 32: Line 32:
 
<td width=300>
 
<td width=300>
  
See [[
+
See [[VTube Communication with YLM Benders]].
[[VTube-STEP]] can export Supravision data to YLM benders.<br><br> 
+
[[VTube-LASER]], the version of VTube that connects to a FARO measuring center arm, can send measured data to the YLM control for corrections.<br><br>
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Revision as of 19:18, 24 June 2015

YLMcncbender.jpg

YLM (Yin Lin Machine Industrial Co.) benders are built in Taiwan and distributed in the Americas by J & S Machine, Inc.

YLMlogo.jpg


YLM Control software

The YLM Windows software allows for complete programming of bender setup.
YLM Main Screen.jpg

YLMsimulator.jpg

VTube-STEP and VTube-LASER Support for YLM Benders

See VTube Communication with YLM Benders.

VTubeToYLM.jpg

Using VTube-LASER to send NEW MASTER Data to YLM Benders

The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer.

For a NEW TUBE, the YLM takes in VTube MASTER Supravision LRA data in a Supravision file.



Follow these steps at VTube-LASER to Send a NEW TUBE SETUP to a YLM Bender

STEP 1
Switch to the MASTER TUBE window and press the FILE tab.

STEP 2
Save the Supravision file.

STEP 3
Move to the YLM control and follow the steps below to import the new data.

Vtube-laser-1.96 SupravisionExportMenu Master.png

Vtube-laser-1.96 SaveMasterSupravisionData.png

Follow these steps at the YLM CONTROL to import the MASTER data from VTube-LASER

STEP 1
In the YLM control, clear the YBC data. (Note:Clearing is optional. It is not always necessary - but seems to keep data from overlapping between older and newer setups.)

YLM YBC Screen.png

STEP 2
In the YLM YBC menu, click on CORRECTION.

Ylm ybc correction button.png

STEP 3
In the lower right corner of the screen, select the drive and path then explore for and select the $$$ file that was created by VTube-LASER.

YLM Import Screen.jpg

STEP 4
In the YLM YBC menu, click on IMPORT. (Do not click "COMPARE" - as that is for corrections.)

YLM YBC NewImport.png

STEP 5
Press the Exit menu close button in the lower right corner of the screen.

YLM YBCCorrections exit.png

STEP 6
In order to exit the YBC screen, you might need to double tap on the teach mode button in order to turn on teach mode. Then double tap on the sequences icon on the top of the sequences column. Reset the sequences.

YLMTeachModeAndSequence.png




VTube-LASER CORRECTION Steps for YLM Benders

The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer.

The YLM control handles corrections differently than any other control. This is how it is unique:

  • First, for a CORRECTION, the YLM takes in VTube MEASURED Supravision LRA data. To make a correction to a YLM bender, it is important to send ONLY this data. The standard correction process will not work with the YLM.

  • Second, the YLM sends the correction the wrong way when taking in the MEASURED data and comparing it to its MASTER or NOMINAL data. The only way overcome this is to use a special INVERSION checkbox in the Supravision Export menu. Only use this inversion switch when sending measured data for correction.


Follow these steps at VTube-LASER to Correct a YLM Bender

STEP 1
Switch to the MEASURED TUBE window and press the FILE tab.

VTube-Laser-1.96 SaveMeasuredTubeData.png

STEP 2
Most YLM benders use the pure MEASURED data for corrections. However, some YLM benders need the MEASURED data changed into the CORRECTED data - and the CORRECTIONS are always made based on the MASTER data (not the existing data in the bender). We call this "YBC Correction Inversion".

If you find that the corrections move in the wrong direction on a YLM, then check the inversion check box. The inversion check box will only display if VTube knows you are saving MEASURED data to a Supravision file.

Vtube-laser-1.96 SupravisionExportMenu.png

STEP 3
Save the Supravision file.

STEP 4
Move to the YLM control and follow the steps below to import the correction.



Follow these steps at the YLM CONTROL to import the measured data from VTube-LASER

STEP 1
In the YLM YBC menu, click on CORRECTION.

Ylm ybc correction button.png

STEP 2
Search for and select the $$$ file that was created by VTube-LASER.

STEP 3
Select COMPARE to bring the data into the YLM control. The COMPARE button will only display when a file is selected.

NOTE: DO NOT press the IMPORT button for corrections. Pressing IMPORT will make the correction data the nominal data - which would be incorrect.

YMC YBC Correction CompareButton.png

STEP 4
Press the menu close button in the lower right corner.

YLM YBCCorrections exit.png

Shutdown to Edit the Windows Setup

To shutdown the YLM software to configure Windows settings:

  1. Press the Shutdown button.

  2. Press "NO" for shutdown.

  3. Type "12345" and OK in the numeric keypad.

  4. YLM will close without shutting down the computer.






Other Pages