Difference between revisions of "Wiring: Finding 120 VAC in a CNC Bender Lite operator station"
(→STEP 3: Locate a Spare Wire that Runs Through the Flexible Conduit) |
(→STEP 4: Attach the Spare Wire to the Neutral) |
||
Line 79: | Line 79: | ||
==STEP 4: Attach the Spare Wire to the Neutral== | ==STEP 4: Attach the Spare Wire to the Neutral== | ||
+ | <table> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | |||
*Attach a terminal pin to end of the spare wire in the operator station. | *Attach a terminal pin to end of the spare wire in the operator station. | ||
− | *Attach the spare wire to the Neutral terminal in the | + | *Attach the spare wire to the Neutral terminal in the |
+ | |||
+ | </td> | ||
+ | <td> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
==Tools/Parts Needed== | ==Tools/Parts Needed== |
Revision as of 17:59, 19 December 2009
Contents |
About
Some original CNC Bender LiteControl operator stations use 24 VDC to power the computer. However, the newer Pro-face units sometimes come with 100-220VAC power supply requirements.
This document shows where to find 120 VAC in these operator stations.
WARNING! |
STEP 1: Open the operator station front cover
This cover uses a hinge at the bottom, so you can swing it down for work inside the operator station.
|
STEP 2: Find the 120VAC
You will find 120VAC on the back of the E-Stop button. (Test this with a multimeter.) The terminal with constant power is usually the right side.
|
STEP 3: Locate a Spare Wire that Runs Through the Flexible Conduit
|
STEP 4: Attach the Spare Wire to the Neutral
|
Tools/Parts Needed
14 Gauge THHN stranded wire |
|
Vinyl Insulate Terminal Pin for 14 gauge wire (See 159-1617 Kobiconn Terminals Pin Blue 16-14 at Mouser.com) |
|
Possibly a jumper bar (Automationdirect.com DINnectors DN-82J10) |
|
Crimper for terminal pins, screw drivers, diagonal cutters for cutting the jumper bar |
Other Pages
- Back to the CNC Bender Page
- Back to the CNC Bender Technical Notes Page