Difference between revisions of "VTube NUMALLIANCE Bender Correction"

From ATTWiki
Jump to: navigation, search
(Created page with "800px<br><br> <table width=1000> <tr valign=top> <td width=300> This page describes the use of the VTube-LASER to OMCG bender corrections...")
 
Line 1: Line 1:
 
[[image:VTube-LASER_OMCGSplash.png|800px]]<br><br>
 
[[image:VTube-LASER_OMCGSplash.png|800px]]<br><br>
 +
[[image:Numalliance Splash.png|500px]]<br><br>
  
 
<table width=1000>
 
<table width=1000>
Line 16: Line 17:
 
__TOC__
 
__TOC__
  
=OMCG SVNet Communications Protocol in VTube-LASER=
+
==NUMALLIANCE CORRECTIONS==
<table width=1000>
+
 
 +
<table cellpadding=10 width=800>
 
<tr valign=top>
 
<tr valign=top>
<td width=300>
 
OMCG added the Supravision Network protocol to their Easy Programming 4 version 2.02 bender control software at the beginning of 2019.<br><br>
 
As of version 2.9.18, we've embedded the OMCG SVNET protocol in VTube-STEP and VTube-LASER.<br><br>
 
You can set this protocol in the Benderlink setup grid in System Options.<br><br>
 
[[image:OMCGSplash.png|300px]]<br><br>
 
</td>
 
<td width=300>
 
[[image:VTube-LASER_OMCGSVNET_BenderSetupScreen.png|700px]]
 
</td>
 
</tr>
 
</table>
 
  
<br><br>
 
 
=Using the OMCG Easy Programming 4 Measuring System Interface=
 
<table width=1000>
 
<tr valign=top>
 
 
<td width=300>
 
<td width=300>
Click on the Measuring System button in the toolbar to load the Measure System Interface.<br><br>
+
VTube-LASER now has an export option for NUMALLIANCE CSV files that is used to '''correct''' the NUMALLIANCE benders.<br><br>
The window allows you to handle both CORRECTIONS and NOMINAL data.
+
Note: NUMALLIANCE benders only require the ''measured'' data for corrections.<br><br>
 +
Measure the tube in VTube-LASER, then send the MEASURED tube data to the bender control, and it will then perform the correction.
  
===NOMINAL EXPORT===
+
</td>
* The NOMINAL EXPORT section allows you to SEND NOMINAL data FROM the OMCG software to VTube-LASER.<br><br>
+
* The NOMINAL EXPORT Enable allows OMCG to automatically respond to a request for NOMINAL data from VTube-LASER.<br><br>
+
  
===NOMINAL IMPORT===
+
<td>
* The NOMINAL IMPORT section allows you to IMPORT VTube-LASER data INTO the OMCG.<br><br>
+
[[image:Numalliance Splash.png|500px]]<br><br>
* In this case, you can load any Supravision file created by VTube-STEP or VTube-LASER into the OMCG control.<br><br>
+
[[image:VTube-LASER Correcting a NUMALLIANCE Bender.png|500px]]
 
+
===CORRECTIONS===
+
* You can set a variety of options to control how you want the data to come into the OMCG control.<br><br>
+
* Recommended settings:<br><br>
+
 
+
# Enable corrections<br><br>
+
# Set Apply Mode to "Ask" in order to confirm that you will allow the corrections to be applied.<br><br>
+
# Apply the corrections to any of the three options.  (Use the checkboxes.)<br><br>
+
 
+
 
+
</td>
+
<td width=300>
+
[[image:OMCGScreen_WithMeasuringSystem.png|700px]]<br><br>
+
----------------
+
[[image:OMCGScreen_MeasuringSystemInterface_Window.png|700px]]
+
 
</td>
 
</td>
 
</tr>
 
</tr>
 +
 
</table>
 
</table>
 
 
<br><br>
 
<br><br>
  
=Configuring the OMCG Measuring System Interface=
 
<table width=1000>
 
<tr valign=top>
 
<td width=300>
 
Click on the setup button in the Measuring System Interface menu to configure the measuring center communications.<br><br>
 
 
===Configuring the Settings===
 
* Bender Name: This is mnemonic. It is to help you know which bender is associated with the bender number.<br><br>
 
* Bender Number: The Supravision network protocol requires that every bend have a unique number if the benders are sharing the same network path for communications.<br><br>
 
* Paths: These are the paths used for VTube-LASER to communicate with the OMCG software.<br><br>
 
* Timeouts: These are timeouts that allow the OMCG to know when it has waited too long for data to move in either direction.<br><br>
 
* Radius Adjust Enable: This allows VTube-LASER to change the radius values with nominal and corrections communications.<br><br>
 
* Allow negative angle: Wire benders can bend left or right depending on the sign of the bend angle. It is normal to make this feature active.<br><br>
 
 
</td>
 
<td width=300>
 
[[image:OMCGScreen_MeasuringSystemInterface_Configuration_Window.png|700px]]
 
</td>
 
</tr>
 
</table>
 
 
 
=OMCG Documentation from OMCG=
 
<table width=1000>
 
<tr valign=top>
 
<td width=300>
 
This is the official OMCG Document (PDF - English) for setup and use of the OMCG SVNET protocol.<br><br>
 
 
Download the [https://www.advancedtubular.com/vtube-laser/20190222%20OMCG%20EP4%20Measuring%20System%20%20ENG%20v1.3.pdf OMCG PDF Setup Document]
 
 
</td>
 
<td width=300>
 
[[image:OMCGScreen_SetupDocument_PDFScreenShot.png|400px]]
 
</td>
 
</tr>
 
</table>
 
  
 
==Other Pages==
 
==Other Pages==
 
* See [[VTube-LASER]]
 
* See [[VTube-LASER]]
 
* See [[VTube-STEP]]
 
* See [[VTube-STEP]]

Revision as of 17:51, 11 July 2019

VTube-LASER OMCGSplash.png

Numalliance Splash.png

This page describes the use of the VTube-LASER to OMCG bender corrections.



Back to VTube-LASER

Contents


NUMALLIANCE CORRECTIONS

VTube-LASER now has an export option for NUMALLIANCE CSV files that is used to correct the NUMALLIANCE benders.

Note: NUMALLIANCE benders only require the measured data for corrections.

Measure the tube in VTube-LASER, then send the MEASURED tube data to the bender control, and it will then perform the correction.

Numalliance Splash.png

VTube-LASER Correcting a NUMALLIANCE Bender.png