VTube Intersection Point Tolerances

From ATTWiki
Revision as of 20:30, 13 August 2014 by Mcone (Talk | contribs)

Jump to: navigation, search

Vtube-laser logo.jpg XYZ Intersection Tolerances

Vtube-laser 1 73.jpg


How the XYZ Intersection Tolerances Work



The XYZ intersection tolerances allow you to quickly qualify a part using +/- tolerances to the intersection points.

The intersection tolerances are based on values are that follow the three axes in a coordinate system. Since the tolerances measure along the axes, as of version 1.93, these tolerances can be positive or negative to also indicate a direction.

Vtube-laser xyz intersection tolerances inspection grid.png

XYZ Intersection Deviations



The XYZ intersection tolerances are based on the XYZ deviations as shown in the model in this screen image.

In this case, most of the error is in the Y axis. It can be verified by seeing that the intersection point of the derived data is visually above the master point. The deviation data indicates that it is exactly 0.012" above the master point in the Y axis.

Vtube-laser-1.94 closeup xyz intersection model.png

Set the Tolerances in Inspection Data Menu

You can set these tolerances in two places in VTube-LASER. The first place is in the Inspection Data menu.

Click on the Change Grid Setup button until you see the tolerances in the grid like we show in the image on the right.

Then select and change any tolerance value. The grid will allow you to edit only the tolerances.

Vtube-laser inspectionresults overall xyz intersection with tolerances.png

Or Set the Tolerances in Expanded Windows

The second place to edit the value is in the VTube-LASER Expanded Window.

Click on the Expanded Window button to display the Expanded Window, and then make changes to the tolerances there.

The benefit of the Expanded Window is that you can view all the tolerances at the same time.

Vtube-laser-1.91-expanded xyz intersection deviation edit tolerance.png

Vtube-laser-1.91-expanded-xyz deviation grid.png

Setting All The Tolerances At The Same Time

The intersection deviation grids allow you to set the default tolerance to every value in a row, column, or even the entire grid using a popup menu

To use this feature, single click on a tolerance value, the right click and choose the action.

Vtube-laser-1.93 popup intersection closeup.png

Vtube-laser intersectiondevation tolerances popup.png

The screen images on the right show an example of before and after changes made to an entire column:

Before Vtube-laser-1.93 popup intersection closeup beforechange.png

After Vtube-laser-1.93 popup intersection closeup afterchange.png

XYZ Intersection +/- Tolerance Values in Printed Reports

The XYZ Intersection deviation values can be included in reports:

  1. plus tolerance values
  2. minus tolerance values
  3. out of tolerance values

Vtube-laser-1.91-report xyz intersection deviation output full.png