Difference between revisions of "VTube Intersection Point Tolerances"

From ATTWiki
Jump to: navigation, search
(Setting All The Tolerances At The Same Time)
(Setting All The Tolerances At The Same Time)
Line 100: Line 100:
 
</table>
 
</table>
  
 +
</td>
 +
</tr>
 +
</table>
 +
 +
 +
 +
==XYZ Intersection +/- Tolerance Values in Printed Reports ==
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=400>
 +
The XYZ Intersection deviation values can be included in reports:
 +
# plus tolerance values<br>
 +
# minus tolerance values<br>
 +
# out of tolerance values<br>
 +
[[image:vtube-laser-1.91-report_xyz_intersection_deviation_output_full.png|400px]]
 +
</td>
 +
<td width=300>
 +
[[image:vtube-laser-1.91-report_xyz_intersection_deviation_output.png|300px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 20:15, 13 August 2014

Vtube-laser logo.jpg XYZ Intersection Tolerances

Vtube-laser 1 73.jpg


How the Tolerances Work



The XYZ intersection tolerances are designed to allow you to qualify a part using +/- tolerances to the intersection.

The intersection tolerances are based on values are that follow the three axes in a coordinate system. Since the tolerances measure along the axes, as of version 1.93, these tolerances can be positive or negative to also indicate a direction.

Vtube-laser xyz intersection tolerances inspection grid.png

Set the Tolerances in Inspection Data Menu

You can set these tolerances in two places in VTube-LASER. The first place is in the Inspection Data menu.

Click on the Change Grid Setup button until you see the tolerances in the grid like we show in the image on the right.

Then select and change any tolerance value. The grid will allow you to edit only the tolerances.

Vtube-laser inspectionresults overall xyz intersection with tolerances.png

Or Set the Tolerances in Expanded Windows

The second place to edit the value is in the VTube-LASER Expanded Window.

Click on the Expanded Window button to display the Expanded Window, and then make changes to the tolerances there.

The benefit of the Expanded Window is that you can view all the tolerances at the same time.

Vtube-laser-1.91-expanded xyz intersection deviation edit tolerance.png

Vtube-laser-1.91-expanded-xyz deviation grid.png

Setting All The Tolerances At The Same Time

The intersection deviation grids allow you to set the default tolerance to every value in a row, column, or even the entire grid using a popup menu

To use this feature, single click on a tolerance value, the right click and choose the action.

Vtube-laser-1.93 popup intersection closeup.png

Vtube-laser intersectiondevation tolerances popup.png

This is an example of before and after changes made to an entire column:

Before Vtube-laser-1.93 popup intersection closeup beforechange.png

After Vtube-laser-1.93 popup intersection closeup afterchange.png


XYZ Intersection +/- Tolerance Values in Printed Reports

The XYZ Intersection deviation values can be included in reports:

  1. plus tolerance values
  2. minus tolerance values
  3. out of tolerance values

Vtube-laser-1.91-report xyz intersection deviation output full.png

Vtube-laser-1.91-report xyz intersection deviation output.png

Other Pages