Difference between revisions of "VTube Communication for BLM VGP3D"

From ATTWiki
Jump to: navigation, search
(THE PROTOCOL for SENDING NEW DATA to the BLM)
(BEND the Corrected Part)
 
(112 intermediate revisions by one user not shown)
Line 6: Line 6:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=500>
 
<td width=500>
This page describes the setup and use of the VTube to BLM communications.<br><br>
+
This page describes the setup and use of the recommended BLM communications protocol for VTube.<br><br>
 
</td>
 
</td>
 
<td width=500>
 
<td width=500>
Line 16: Line 16:
 
__TOC__
 
__TOC__
  
==General Communications Setup at the BLM Bender for Both Protocols==
+
=PROTOCOL 1: BLM SVNET PROTOCOL (SW0453)=
 
+
<table>
+
<tr valign=top>
+
<td width=500>
+
 
+
* Connect the BLM bender to the network.<br><br>
+
* Connect the VTube-LASER computer to the network.<br><br>
+
* Setup a shared network location either in the BLM windows control or in a network path on your network.<br><br>
+
* If you share a folder on the BLM control, then create a user with a username and password that can be used to login to the computer from the VTube-LASER computer.<br><br>
+
* If you are using the BLM CMM protocol, then on the VGP3D you must map to the shared network drive.  The drive letter for the map must be Z:\. (This is a fixed letter inside VGP3D logic.)
+
 
+
</td>
+
<td width=300>
+
[[image:ethernet cable orange.png|400px]]
+
</td>
+
</tr>
+
</table>
+
 
+
 
+
 
+
==THE PROTOCOL for SENDING NEW DATA to the BLM==
+
 
<table width=1000>
 
<table width=1000>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=500>
 
<td width=500>
As of early 2019, VTube-LASER supports one protocol for sending new data to the BLM VGP3D control.<br><br>
 
 
===BLM B-IMPORT===
 
Use BLM B-Import to import a STEP file from VTube-LASER or VTube-STEP.
 
 
</td>
 
<td width=500>
 
</td>
 
</tr>
 
</table>
 
 
<br><br>
 
<br><br>
 
+
* The BLM SVNET protocol is the PREFERRED PROTOCOL for CORRECTING the BLM.<br><br>
=HOW TO SEND NEW DATA to BLM Through B-Import=
+
* This protocol uses standard Windows networking.<br><br>
 
+
* Typically, there is a charge from BLM for this protocol to be switched on. The BLM catalog number is "SW0453".  Contact BLM for the price and how to have it switched on in the bender.  A BLM technician will work with your IT department to install and enable the protocol if you purchase it.<br><br>
This is the new method of sending new part data to the BLM control from VTube-STEP and VTube-LASER. It requires the B-Import option - which is an addon option for the BLM control.
+
* This protocol can send and receive corrected bender XcYcZc, part number, diameter, wall thickness, cut length, and radii values.<br><br>
 
+
* The communication is bi-directional to and from the bender. It is possible for VTube-LASER to SEND and RECALL XcYcZc bender data to/from the BLM control.<br><br>  
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
 
+
===Create a STEP file of the MASTER tube at VTube-LASER===
+
Use the File menu in VTube-LASER to export the master STEP model to BLM.<br><br>
+
Be sure that only the STEP model is visible on the screen, then export the STEP model to a folder location that the B-Import program at BLM can also find.
+
 
</td>
 
</td>
<td width=400>
 
[[image:vtl_export_step_filemenu.png|600px]]<br><br>
 
[[image:vtl_export_step_filemenu_closeup_menu_open.png|600px]]<br><br>
 
</td>
 
</tr>
 
</table>
 
 
 
===Import the STEP Into B-Import===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
At the BLM control, load B-Import and import the STEP file.</td>
 
<td width=400>
 
[[image:vtl_blm_b-import.png|600px]]<br><br>
 
</td>
 
</tr>
 
 
</table>
 
 
 
==THE PROTOCOL for SENDING CORRECTION DATA to BLM==
 
<table width=1000>
 
<tr valign=top>
 
 
<td width=500>
 
<td width=500>
As of early 2019, VTube-LASER supports the BLM CMM protocol for correction.<br><br>
+
[[image:ethernet cable orange.png|200px]]
 
+
[[image:BLM control.png|300px]]<br><br>
===BLM CMM PROTOCOL===
+
* The '''BLM CMM''' protocol was introduced in VTube-LASER version 2.9.18.
+
* It is the preferred protocol because it is very easy to use and does not interfer with custom commands inside the BLM VGP3D control.
+
* BLM may charge for this protocol to be switched on.
+
* The BLM catalog number is "SW0842".
+
* This protocol can send centerline UVW, bender XcYcZc, part number, diameter, wall thickness, cut length, and radii values.<br><br>
+
* This protocol is only for bender corrections - not sending new data.
+
 
+
</td>
+
<td width=500>
+
[[image:BLM control.png|600px]]<br><br>
+
 
</td>
 
</td>
 
</tr>
 
</tr>
</table>
 
<br><br>
 
  
 
==BLM CMM CORRECTIONS PROTOCOL: The Capabilities==
 
<table width=1000>
 
<tr valign=top>
 
<td width=500>
 
* VTube-LASER RECALLS, MODIFIES, and SAVES data directly in "CMM.txt" files that the VGP3D software can export and import. Per the instructions above, a communications link can be setup through a standard Windows network connection.<br><br>
 
 
* The communication is bi-directional to and from the bender. It is possible to RECALL data from the BLM using the CMM.txt file format.<br><br>
 
 
* The data that is included in the BLM CMM.txt file that the BLM can read/write is the '''UVW data (the tube centerline data)''', the '''BENDER data (Xc axis, Yc Axis, Zc Axis)'''. The data also includes the '''diameter''', '''wall''', '''cut length''', and all '''radii'''.<br><br>
 
 
</td>
 
<td width=500>
 
[[image:blm_vgp3d_screen_xcyczc.png|600px]]<br><br>
 
 
</td>
 
</tr>
 
 
</table>
 
</table>
 
<br><br>
 
<br><br>
  
==NEWER BLM CMM CORRECTIONS PROTOCOL: Setup Benderlink at VTube-STEP or VTube-LASER with the BLM CMM Protocol==
+
==Setup the BLM SVNET Protocol in VTube-LASER==
  
  
===Entering Benderlink Setup===
+
===Entering VTube-LASER Benderlink Setup===
 
<table>
 
<table>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
 
#Enter the VTube System Options menu.<br><br>
 
#Enter the VTube System Options menu.<br><br>
#Enter the Measure 2 tab menu.<br><br>
+
#Enter the Global List tab menu.<br><br>
 
#Enter the Setup Benderlink Network menu.<br><br>
 
#Enter the Setup Benderlink Network menu.<br><br>
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:VTube System Options Benderlink Network Button.png|600px]]
+
[[image:BenderlinkSetupButton.png|600px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
  
===Setup the Benderlink Network Grid for the BLM CMM Protocol===
+
===Setup the Benderlink Network Grid for the BLM SVNET Protocol===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
Line 151: Line 59:
 
#Choose an unused row in the grid for a new BLM bender setup. (Click on the image at the right to see a zoomed image.)<br><br>
 
#Choose an unused row in the grid for a new BLM bender setup. (Click on the image at the right to see a zoomed image.)<br><br>
 
#Assign a bender name that will help operators identify what this bender is.  This text will be displayed at the top of the Bender Setup menu.<br><br>
 
#Assign a bender name that will help operators identify what this bender is.  This text will be displayed at the top of the Bender Setup menu.<br><br>
#Set the protocol to BLM CMM (not BLM Data).<br><br>
+
#Set the protocol to BLM SVNET.<br><br>
 
#Enter the path to the shared drive or folder in the NetPath field. Use the same location as the BLM setup. VTube accepts UNC names as well as regular paths with drive letters.<br><br>
 
#Enter the path to the shared drive or folder in the NetPath field. Use the same location as the BLM setup. VTube accepts UNC names as well as regular paths with drive letters.<br><br>
 
#Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)<br><br>
 
#Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)<br><br>
#Most BLM benders handle Positive rotations as Clockwise, so you will probably need to enter "YES" for this option (so that the rotations are not corrected in the wrong direction).<br><br>
+
#Most BLM benders handle Positive rotations as a Clockwise motion, so you will probably need to enter "YES" for these options (so that the rotations are not corrected in the wrong direction).<br><br>
#Press Close to save the settings.  VTube will save these values to a persistent configuration file that will not change unless you change them in this grid.
+
#Press Close to save the settings.  VTube will save these values to a global configuration file that will not change unless you change them in this grid.
  
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_benderlink_blmcmm_pulldown_setup.png|600px]]<br><br>
+
[[image:vtube-laser_benderlink_blmsvnet_pulldown_setup.png|600px]]<br><br>
[[image:vtube-laser_benderlink_blmcmm_row_setup.png|600px]]<br>
+
[[image:vtube-laser_benderlink_blmsvnet_pulldown_closeup_setup.png|600px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 168: Line 76:
 
<br><br>
 
<br><br>
  
==NEWER BLM CMM PROTOCOL: How to SEND CORRECTION Data to the BLM Control from VTube-LASER==
+
==How to SEND a CORRECTION to the BLM Control from VTube-LASER==
  
 
<table cellpadding=10>
 
<table cellpadding=10>
Line 174: Line 82:
 
<td width=300>
 
<td width=300>
  
===Bend the Part on the BLM then Create the CMM.txt File===
+
===Bend the Part on the BLM then Open Measuring Center Communications in VGP3D===
Click on the measuring center image to to right of the part number.
+
Click on the measuring center image to the right of the part number.
 
<br><br>
 
<br><br>
Press the checkmark button to save a new CMM.txt file to Z: drive.<br><br>
+
This will display a small communications window on top of the VGP3D user interface.<br><br>
(This step assumes that you have already mapped the shared network drive to Z drive in the VGP3D control.)
+
The window will allow the BLM to respond to requests for communication from VTube-LASER.<br><br>
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:vtl_blmcmm_savecmmfile.png|600px]]<br><br>
+
[[image:blm_measuringcentericon.png|600px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
 
  
  
Line 224: Line 131:
 
<td width=300>
 
<td width=300>
  
These steps assume that you have programmed a part into the bender, and that you have measured and aligned a part.<br><br>
+
These steps assume that you have programmed a part into the bender and that you have measured and aligned a part.<br><br>
  
STEP 1 - Set the correct bender number at the top of the window. The BLM CMM bender should display if you have already setup the bender protocol in the Benderlink grid.
+
STEP 1 - Set the correct bender number at the top of the window. The BLM SVNET bender icon should display if you have already set up the bender protocol in the Benderlink grid.
  
  
Line 234: Line 141:
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:VTL RECALL from BLM CMM.png|600px]]<br>
+
[[image:VTL RECALL from BLM SVNET.png|600px]]<br>
 +
[[image:VTL RECALL in progress from BLM SVNET.png|600px]]<br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 249: Line 157:
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:VTL BLM CMM RECALL increase Bend Count.png|600px]]<br><br>
+
[[image:VTL BLM SVNET RECALL use incoming part number.png|600px]]<br><br>
[[image:VTL BLM CMM RECALL use incoming part number.png|600px]]<br><br>
+
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 265: Line 172:
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:VTL BLM CMM RECALL Complete.png|600px]]<br><br>
+
[[image:VTL BLM SVNET RECALL Complete.png|600px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 272: Line 179:
 
<br><br>
 
<br><br>
  
===SEND THE CORRECTIONS INTO THE BLM CMM FILE===
+
===SEND THE CORRECTIONS TO THE BLM FILE===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
  
SAVE the Correction data to the file for the BLM CMM.txt file by pressing AUTO SEND BENDER CORRECTIONS.
+
SAVE the Correction data to the file for the BLM by pressing AUTO SEND BENDER CORRECTIONS.
 
<br><br>
 
<br><br>
 
STEP 1 - Click on Bidirectional Communication<br><br>
 
STEP 1 - Click on Bidirectional Communication<br><br>
 
STEP 2 - Click on AUTO SEND BENDER CORRECTIONS.<br><br>
 
STEP 2 - Click on AUTO SEND BENDER CORRECTIONS.<br><br>
 
<br><br>
 
<br><br>
This will change the contents of the BLM CMM.txt file to the values in the ORANGE cells.<br><br>
+
This will change the contents of the BLM XYZ to the values from the VTube ORANGE cells.<br><br>
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:VTL BLM CMM Send Send Correction.png|600px]]<br><br>
+
[[image:VTL BLM SVNET Send Send Correction.png|600px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 291: Line 198:
 
<br><br>
 
<br><br>
  
===AT THE BLM, PRESS the CHECKMARK Button===
+
===AT THE BLM, Close the Communications Window===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
If you saved the orange columns of data from VTube-LASER to the CMM.txt file, then it is very important to press the checkmark "yes" button for BLM to import the new CMM.txt file data.<br><br>
+
If you sent the correction data (the orange columns of data) from VTube-LASER to the BLM, then you can close the BLM communications window at the BLM and then check the new XYZc bender values. Be sure that they match the data in the orange cells in VTube.<br><br>
After you press the checkmark button, the new data will display in the XYZc menu grid.<br><br>
+
It's a good idea to cross-check a value (like the first bend angle) to be sure that the new data was imported correctly.<br><br>
+
 
+
 
+
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:VTL BLM CMM Correction Acqiure.png|600px]]<br><br>
 
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 308: Line 210:
 
<br><br>
 
<br><br>
  
===SIMULATE and RUN===
+
===BEND the Corrected Part===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
Line 314: Line 216:
  
  
* Run the simulator with the new data.<br><br>
+
* The XYZc data will be updated. Run the simulator with the new data.<br><br>
 
* Bend the corrected part.<br><br>
 
* Bend the corrected part.<br><br>
* Press the measuring center icon in the upper right corner to build the CMM.txt file in Z drive.<br><br>
+
* In the VGP3D software, press the measuring center icon again to be ready for communications from VTube-LASER in case another correction is needed.<br><br>
* Take the part back to VTube-LASER to measure it again for qualification.
+
* Take the part back to VTube-LASER to measure it again for qualification. (Repeat the process from [[#Measure the tube with VTube-LASER|"Measure the tube with VTube-LASER"]] above.)
 +
 
 +
 
 +
 
  
 
</td>
 
</td>
Line 331: Line 236:
 
<td width=300>
 
<td width=300>
  
* A RECALL from the BLM must be performed firstVTube will not build a NEW CMM.txt file during corrections.<br><br>
+
* A RECALL from the BLM must be performed first so that VTube learns the data that is currently used to bend the part that you just measured.<br><br>
* Therefore, it is critical to create a CMM.txt file on Z drive at the VGP3D before walking over the measuring center.<br><br>
+
* The number of bends must match in both VTube-LASER and BLM.<br><br>
* The number of bends must match in both VTube-LASER and the BLM CMM.txt file.<br><br>
+
* While the corrections loop does not use the UVW data from the VGP3D control for corrections, it will retain whatever UVW values are there. This prevents VTube-LASER from disturbing the UVW values during the corrections loop process.<br><br>
+
* If you change the part number, diameter, wall thickness, or cut length, then those values will also change in VGP3D when you send the corrections.
+
 
+
  
 
<br><br>
 
<br><br>
Line 348: Line 249:
 
<br><br>
 
<br><br>
  
==NEWER BLM CMM PROTOCOL: How to Convert BLM UVW into VTube-LASER MASTER Data==
+
=Other Pages=
 
+
* See also [[VTube Communication for BLM VGP3D - Alternative Protocols]]
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
 
+
===Create a CMM.txt file at the BLM VGP3D Control===
+
Click on the measuring center image to to right of the part number.
+
<br><br>
+
Press the checkmark button to save a new CMM.txt file to Z: drive.<br><br>
+
</td>
+
<td width=400>
+
[[image:vtl_blmcmm_savecmmfile.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
 
+
===Enter the Setup this Window Menu===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
Go to the VTube-LASER software and...
+
* Choose the correct bender number.<br><br>
+
* Click on "Setup this Window" in the office bar menu on the right.
+
</td>
+
<td width=400>
+
[[image:vtl_blmcmm_SetupThisWindowButton.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
===Recall the Bender XYZ===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
* Click on RECALL Bender XYZ to Master XYZ.
+
</td>
+
<td width=400>
+
[[image:vtl_blmcmm_RecallBenderXYZtoMasterXYZ.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
===Press Continue===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
* Press Continue.
+
</td>
+
<td width=400>
+
[[image:vtl_blmcmm_RecallBenderXYZtoMasterXYZ_Continue.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
===MASTER PART Displayed===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
The new master part will be displayed in the main VTube-LASER screen.
+
</td>
+
<td width=400>
+
[[image:vtl_blmcmm_RecallBenderXYZtoMasterXYZ_MasterPartImage.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
 
+
 
+
<br><br>
+
 
+
=OLDER LEGACY BLM DATA Protocol Section=
+
 
+
==LEGACY BLM DATA PROTOCOL: The Capabilities==
+
<table width=1000>
+
<tr valign=top>
+
<td width=500>
+
* VTube-LASER RECALLS, MODIFIES, and SAVES data directly in ".BLM" files. A communications link can be setup through a standard Windows network connection.<br><br>
+
 
+
* The communication is bi-directional to and from the bender. It is possible to RECALL data from the BLM using the .BLM file format.<br><br>
+
 
+
* The data that is included in the BLM file that the BLM can read is the '''BENDER data (Xc axis, Yc Axis, Zc Axis)'''. The data also includes the '''diameter''' and the '''cut length'''.<br><br>
+
 
+
* The protocol does not send the RADIUS data. Sending radius data causes the VGP3D to reset the tools and rebuild all custom commands - so VTube-LASER avoids sending this data.<br><br>
+
 
+
</td>
+
<td width=500>
+
[[image:blm_vgp3d_screen.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
<br><br>
+
 
+
==LEGACY BLM DATA PROTOCOL: Setup Benderlink at VTube-STEP or VTube-LASER==
+
 
+
===Entering Benderlink Setup===
+
<table>
+
<tr valign=top>
+
<td width=300>
+
#Enter the VTube System Options menu.<br><br>
+
#Enter the Measure 2 tab menu.<br><br>
+
#Enter the Setup Benderlink Network menu.<br><br>
+
</td>
+
<td width=300>
+
[[image:VTube System Options Benderlink Network Button.png|600px]]
+
</td>
+
</tr>
+
</table>
+
 
+
===Setup the Benderlink Network Grid for the BLM Bender===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
#Choose an unused row in the grid for a new BLM bender setup. (Click on the image at the right to see a zoomed image.)<br><br>
+
#Assign a bender name that will help operators identify what this bender is.  This text will be displayed at the top of the Bender Setup menu.<br><br>
+
#Set the protocol to BLM Data.<br><br>
+
#Enter the path to the shared drive or folder in the NetPath field. Use the same location as the BLM setup. VTube accepts UNC names as well as regular paths with drive letters.<br><br>
+
#Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)<br><br>
+
#Most BLM benders handle Positive rotations as Clockwise, so you will probably need to enter "YES" for this option (so that the rotations are not corrected in the wrong direction).<br><br>
+
#Press Close to save the settings.  VTube will save these values to a persistent configuration file that will not change unless you change them in this grid.
+
 
+
</td>
+
<td width=300>
+
[[image:vtube-laser_benderlink_blm_setup.png|600px]]
+
</td>
+
</tr>
+
 
+
</table>
+
 
+
<br><br>
+
 
+
==LEGACY BLM DATA PROTOCOL: How to SEND CORRECTION Data to the BLM Control from VTube-LASER==
+
 
+
===After Bending the Tube===
+
Bend a tube then measure it with VTube-LASER.<br><br>
+
 
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
 
+
===Measure the tube with VTube-LASER===
+
Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.
+
<br><br>
+
In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance.
+
</td>
+
<td width=400>
+
[[image:vtube-laser_v2.7_soco_part_measure.png|600px]]<br><br>
+
[[image:vtube-laser_v2.7_soco_out_of_tolerance.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
 
+
===Correct the BLM with VTube-LASER - Enter BENDER SETUP===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
Follow these steps in the VTube-LASER:
+
 
+
Press the "BENDER SETUP button in the Navigation Pane.
+
</td>
+
<td width=400>
+
[[image:vtube-laser_2.7_bendersetup_button_navigationpane.png|400px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
===INITIAL RECALL Setup of Bender Setup Window===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
 
+
The first time in this window for a new part will require these steps before you can correct the BLM bender. These steps assume that you have programmed a part in the bender, and that you have measured and aligned a part.<br><br>
+
 
+
STEP 1 - Set the correct bender number at the top of the window. The BLM bender should display if you have already setup the bender protocol in the Benderlink grid.
+
 
+
 
+
STEP 2 - Click on the "Bidirectional Communication" button.
+
 
+
 
+
STEP 3 - Click on the "RECALL LRA from BENDER" button.
+
 
+
 
+
STEP 4 - Select the BLM file to open.
+
 
+
</td>
+
<td width=400>
+
[[image:VTL Initial RECALL from BLM.png|600px]]<br>
+
[[image:VTL Initial Recall from BLM with open dialog.png|600px]]
+
</td>
+
</tr>
+
</table>
+
 
+
 
+
===RECALL Warning Boxes===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
VTube-LASER will probably warn you that the incoming data count and part number does not match what is in VTube-LASER.
+
<br><br>
+
* It is very important that you allow the incoming bender data to increase the bend count to whatever is at the bender.<br><br>
+
* If you want the Part Number at the bender to be left untouched, then just accept the incoming part number and use it for transfer from this point forward.
+
</td>
+
<td width=400>
+
[[image:VTL BLM RECALL increase Bend Count.png|600px]]<br><br>
+
[[image:VTL BLM RECALL use incoming part number.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
<br><br>
+
 
+
===THE BLUE COLUMNS SHOULD MATCH THE BLM XYZc DATA AFTER THE RECALL===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
After the RECALL, the blue columns should show the data that is programmed in the BLM control.<br><br>
+
This ensures that corrections are being made to the correct foundational data. If the blue column data does not match the bender at correction time, then it is probable that the bender will not be corrected properly.
+
</td>
+
<td width=400>
+
[[image:VTL BLM RECALL Complete.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
<br><br>
+
 
+
===MERGE THE CORRECTIONS INTO THE BLM FILE===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
 
+
MERGE and SAVE the Correction data to the file for the BLM to import by pressing AUTO SEND BENDER CORRECTIONS.
+
<br><br>
+
STEP 1 - Click on Bidirectional Communication<br><br>
+
STEP 2 - Click on AUTO SEND BENDER CORRECTIONS.<br><br>
+
<br><br>
+
This will change the contents of the BLM file to the values in the ORANGE cells.<br><br>
+
VTube also makes a backup of the current setup to a .blm$ file in case you want to undo that last correction.
+
</td>
+
<td width=400>
+
[[image:VTL BLM Send Send Correction.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
<br><br>
+
 
+
===THESE ARE THE DIALOGS INSIDE THE AUTO SEND FEATURE===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
DIALOG 1 - The first dialog explains how communications works. This is for any user that needs to be reminded of how the merge process works.<br><br>
+
DIALOG 2 - In the SAVE dialog, select the BLM file to merge data into, then press Save.<br><br>
+
DIALOG 3 - VTube will show a timed message about the data merge.
+
 
+
</td>
+
<td width=400>
+
[[image:VTL BLM Send Correction Explanation Dialog.png|600px]]<br><br>
+
[[image:VTL BLM Send Correction with Open Dialog.png|600px]]<br><br>
+
[[image:VTL BLM Send Correction with Timed Message.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
<br><br>
+
 
+
===AFTER CORRECTION - LOAD THE NEW BLM FILE INTO THE VGP3D SOFTWARE AT THE BLM CONTROL===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
 
+
Load the BLM data VTube just saved into the VGP3D software.
+
<br><br>
+
[[image:BLM control.png|300px]]
+
</td>
+
<td width=400>
+
[[image:VTL BLM VGP-3D XYZc Screen.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
===CRITICAL STEP: Recalculate the BLM Memory Following These Easy Steps===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
 
+
This next step is CRITICAL for proper operation of the BLM software.  Without it, the new data will not be sent to the PLC.<br><br>
+
* Touch any value on the XYZc grid.<br><br>
+
* Without changing the value, press the Enter button (the pen button).<br><br>
+
This will recalculate the internal BLM data.<br><br>
+
'''IF YOU DO NOT TAKE THIS STEP, THEN THE XYZc VALUES ON THE SCREEN WILL NOT BE THE VALUES IN THE POINT TABLE THAT CONTROLS THE BENDER MOTION.'''
+
 
+
</td>
+
<td width=400>
+
[[image:VTL BLM VGP-3D XYZc Screen Enter Change.png|600px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
===SIMULATE and RUN===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
 
+
 
+
* Run the simulator with the new data.<br><br>
+
* Bend the corrected part.<br><br>
+
* Take the part back to VTube-LASER to measure it again for qualification.
+
 
+
</td>
+
<td width=400>
+
[[image:blm_elect80.png]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
===THE IMPORTANCE OF NOT RENAMING THE BLM FILE DURING CORRECTIONS===
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
'''In order to retain custom moves already setup in VGP3D, it is important that you DO NOT CHANGE the .BLM filename during corrections.'''<br><br><br>
+
====Why?====
+
The .BLM file that VTube-LASER modifies is accompanied by a point table file with the same filename but with a different filename extension of .OUT.<br><br>
+
For example, on the BLM control, if there is a file "12345678.BLM" and you have bent the part, then there is a file "12345678.OUT" which represents the point table.<br><br>
+
The .OUT file can contain custom lines that an operator programmed into the BLM for avoidance moves. If the .OUT file exists, then the SIMULATION CONTROL buttons (shown on the right) will be colored blue or green. If the .OUT file does not exist, then they will be grey - and the point table will need to be rebuilt. <br><br>
+
 
+
</td>
+
<td width=400>
+
[[image:vgp3d_simulation controls.png]]<br><br>
+
</td>
+
</tr>
+
</table>
+
 
+
==Other Pages==
+
 
* See [[VTube-LASER]]
 
* See [[VTube-LASER]]
 
* See [[VGP3D]]
 
* See [[VGP3D]]
 
* See [[BLM]] for information about BLM Group
 
* See [[BLM]] for information about BLM Group

Latest revision as of 14:37, 14 July 2022

Vtl2blm.png Blm elect80.png

About this Page

This page describes the setup and use of the recommended BLM communications protocol for VTube.

Contents


PROTOCOL 1: BLM SVNET PROTOCOL (SW0453)



  • The BLM SVNET protocol is the PREFERRED PROTOCOL for CORRECTING the BLM.

  • This protocol uses standard Windows networking.

  • Typically, there is a charge from BLM for this protocol to be switched on. The BLM catalog number is "SW0453". Contact BLM for the price and how to have it switched on in the bender. A BLM technician will work with your IT department to install and enable the protocol if you purchase it.

  • This protocol can send and receive corrected bender XcYcZc, part number, diameter, wall thickness, cut length, and radii values.

  • The communication is bi-directional to and from the bender. It is possible for VTube-LASER to SEND and RECALL XcYcZc bender data to/from the BLM control.

Ethernet cable orange.png BLM control.png



Setup the BLM SVNET Protocol in VTube-LASER

Entering VTube-LASER Benderlink Setup

  1. Enter the VTube System Options menu.

  2. Enter the Global List tab menu.

  3. Enter the Setup Benderlink Network menu.

BenderlinkSetupButton.png

Setup the Benderlink Network Grid for the BLM SVNET Protocol

  1. Choose an unused row in the grid for a new BLM bender setup. (Click on the image at the right to see a zoomed image.)

  2. Assign a bender name that will help operators identify what this bender is. This text will be displayed at the top of the Bender Setup menu.

  3. Set the protocol to BLM SVNET.

  4. Enter the path to the shared drive or folder in the NetPath field. Use the same location as the BLM setup. VTube accepts UNC names as well as regular paths with drive letters.

  5. Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)

  6. Most BLM benders handle Positive rotations as a Clockwise motion, so you will probably need to enter "YES" for these options (so that the rotations are not corrected in the wrong direction).

  7. Press Close to save the settings. VTube will save these values to a global configuration file that will not change unless you change them in this grid.

Vtube-laser benderlink blmsvnet pulldown setup.png

Vtube-laser benderlink blmsvnet pulldown closeup setup.png



How to SEND a CORRECTION to the BLM Control from VTube-LASER

Bend the Part on the BLM then Open Measuring Center Communications in VGP3D

Click on the measuring center image to the right of the part number.

This will display a small communications window on top of the VGP3D user interface.

The window will allow the BLM to respond to requests for communication from VTube-LASER.

Blm measuringcentericon.png


Measure the tube with VTube-LASER

Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.

In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance.

Vtube-laser v2.7 soco part measure.png

Vtube-laser v2.7 soco out of tolerance.png


Correct the BLM with VTube-LASER - Enter BENDER SETUP

Follow these steps in the VTube-LASER:

Press the "BENDER SETUP button in the Navigation Pane.

Vtube-laser 2.7 bendersetup button navigationpane.png

INITIAL RECALL Setup of Bender Setup Window

These steps assume that you have programmed a part into the bender and that you have measured and aligned a part.

STEP 1 - Set the correct bender number at the top of the window. The BLM SVNET bender icon should display if you have already set up the bender protocol in the Benderlink grid.


STEP 2 - Click on the "RECALL LRA from BENDER" button.


VTL RECALL from BLM SVNET.png
VTL RECALL in progress from BLM SVNET.png

RECALL Warning Boxes

VTube-LASER will probably warn you that the incoming data count and part number does not match what is in VTube-LASER.

  • It is very important that you allow the incoming bender data to increase the bend count to whatever is at the bender.

  • If you want the Part Number at the bender to be left untouched, then just accept the incoming part number and use it for transfer from this point forward.

VTL BLM SVNET RECALL use incoming part number.png



THE BLUE COLUMNS SHOULD MATCH THE BLM XYZc DATA AFTER THE RECALL

After the RECALL, the blue columns should show the data that is programmed in the BLM control.

This ensures that corrections are being made to the correct foundational data. If the blue column data does not match the bender at correction time, then it is probable that the bender will not be corrected properly.

VTL BLM SVNET RECALL Complete.png



SEND THE CORRECTIONS TO THE BLM FILE

SAVE the Correction data to the file for the BLM by pressing AUTO SEND BENDER CORRECTIONS.

STEP 1 - Click on Bidirectional Communication

STEP 2 - Click on AUTO SEND BENDER CORRECTIONS.



This will change the contents of the BLM XYZ to the values from the VTube ORANGE cells.

VTL BLM SVNET Send Send Correction.png



AT THE BLM, Close the Communications Window

If you sent the correction data (the orange columns of data) from VTube-LASER to the BLM, then you can close the BLM communications window at the BLM and then check the new XYZc bender values. Be sure that they match the data in the orange cells in VTube.



BEND the Corrected Part


  • The XYZc data will be updated. Run the simulator with the new data.

  • Bend the corrected part.

  • In the VGP3D software, press the measuring center icon again to be ready for communications from VTube-LASER in case another correction is needed.

  • Take the part back to VTube-LASER to measure it again for qualification. (Repeat the process from "Measure the tube with VTube-LASER" above.)



Blm elect80.png

IMPORTANT RULES for CORRECTIONS LOOPS

  • A RECALL from the BLM must be performed first so that VTube learns the data that is currently used to bend the part that you just measured.

  • The number of bends must match in both VTube-LASER and BLM.



BLM control.png