VTube-STEP v2.3

From ATTWiki
Revision as of 21:22, 10 February 2016 by Mcone (Talk | contribs)

Jump to: navigation, search

Vtube-step logo 2.png

Revision 2.3

Vtube-step-1.87 screenimage.png

Contents




Check.jpg NEW: Springback-Compensated LRA Grids

Both VTube-STEP and VTube-LASER now have Springback-Compensated grids in the Tube data, Master Tube data, and the Measured Tube data menus.

The new grids have popup menus that allow you to copy any part of the grid.

Vtube v2.2 springback grid popupmenu.png

Vtube-step v2.2 springback compensated grid.png

Check.jpg NEW: Multi-Elongation Percentage Compensation

VTube-STEP now allows each bend to have a unique tube elongation percentage - which is used to calculate correct CUT LENGTHS and UNBENDING LENGTHS

Use the popup menus in either the PART SETUP or the XYZ grids to get to the setup window.

Vtube v2.2 XYZpopup multielongationsetup.png

A new checkbox is added at the bottom of Part Setup to allow this feature to be activated.

Vtube v2.2 partsetup multielongationsetup switch.png

If the checkbox is unchecked, then the single Tube Elongation % value is used to calculate elongation for all bends.

Vtube v2.2 multielongation setup window.png

Check.jpg FIX: Springback Compensation for Bender Output

When VTube-STEP calculated springback into bender values, it incorrectly doubled the springback values. This has been repaired.


Check.jpg ENHANCEMENT: Springback Compensation Calculation in the Outgoing Bender Data Is Now Optional

This feature adds springback compensation into the outgoing LRA data. In previous versions it was not optional.

For some benders, like the Eaton Leonard LIGHTSPEED, this addition is NOT recommended, because controls like LIGHTSPEED will automatically add the springback compensation based on the springback settings that are also included in the output data.

If you're not sure if you should use this option, then determine how your bender uses the springback compensation values by adding Springback values of non-zero in the Part Setup menu, then running tests with and without this feature activated. If the values end in the control with overbend doubled, then you know that the control handles the springback compensation automatically - and this feature should not be used.

Vtube-step v2.3 benderoutput svnetwork springbackoption.png

Check.jpg Miscellaneous Changes

  • Dashes and zeros for non-functioning values in the XYZ and LRA grids are now replaced with white spaces.
  • The state of the Automatic Refresh Image checkbox in the Report page was not stored and recalled. Now it is.
  • The image refresh for the report menu was changed to work better on slower computers.

Other