Difference between revisions of "VTube-LASER v2.9.6"

From ATTWiki
Jump to: navigation, search
(25pxNEW- SUPRAVISION STYLE OOT CHARACTER)
(25pxNEW- SUPRAVISION STYLE OOT CHARACTER)
Line 67: Line 67:
  
 
<td width=400>
 
<td width=400>
Supravision displayed all deviations with an asterisk.  VTube-LASER can now do the same.<br><br>
+
Supravision displayed all deviations with an asterisk next to them in reports.  VTube-LASER can now do the same.<br><br>
 
However, VTube-LASER allows you to configure the out-of-tolerance text to use in System Options.<br><br>
 
However, VTube-LASER allows you to configure the out-of-tolerance text to use in System Options.<br><br>
 
[[image:vtl_oot_character_report.png|400px]]
 
[[image:vtl_oot_character_report.png|400px]]

Revision as of 00:45, 14 March 2018

Vtube-laser logo 1.96.png


Revision 2.9.6

Release Date: March 13, 2018
Build: 6


Vtube-laser v2.7 screenshot.png

Contents


Check.jpgNEW - AB Length Tolerances in the User Interface

We added AB Length + and - tolerances to VTube-LASER.

VTL AB Length Tolerances Green.png

VTL AB Length Tolerances Red.png



Check.jpgNEW - AB Length Tolerances in the Reports

We added AB Length + and - tolerances to VTube-LASER for reports too.

VTL AB Length Tolerances Reports.png



Check.jpgNEW- SUPRAVISION STYLE OOT CHARACTER

Supravision displayed all deviations with an asterisk next to them in reports. VTube-LASER can now do the same.

However, VTube-LASER allows you to configure the out-of-tolerance text to use in System Options.

Vtl oot character report.png

VTL System Options OOT Text.png



Check.jpgNEW - SEPARATE PERSPECTIVE MODES FOR STEP and LASER WINDOWS

In previous versions, there was only a single Perspective Mode switch.

In this version, there is a separate Perspective Mode switch for STEP and LASER windows.

Vtl 2.9.5 perspective.png
Vts 2.9.5 perspective.png




Check.jpgNEW - REQUEST REVERSE CALC WHEN EXITING THE LRA GRIDS

When you edit the data in the LRA grid, VTube-LASER now assumes that you probably mean to perform a reverse calc.

If you exit the grid without a reverse calc, then it will immediately ask if you intended to perform a Reverse Calc - and allow you to choose to calculate the XYZ data.

This is active in both the MASTER and the MEASURED LRA grids.

Vtl 2.9.5 request reverse calc.png





Check.jpgFIX - REPAIRED LOSS OF ORIGINAL ORIENTATION DURING REVERSE CALC

VTube always attempts to keep the original XYZ orientation when you perform a Reverse Calc from LRA to centerline XYZ data.

We discovered that certain situations would cause VTube to lose the orientation during Reverse Calc.

This has been fixed in this version.

Vts 2.9.5 reversecalc loss orientation.png

Vts 2.9.5 reversecalc noloss orientation.png



Check.jpgFIX - BUILD TO TUBE TO SOLIDWORKS

VTube would incorrectly build a single tube to both a single part drawing and a SOLIDWORKS assembly.

If VTube is building a single tube in SOLIDWORKS the best action is to always build a single part drawing.

The build logic has been fixed in this version.

If there are multiple parts in VTube, then VTube will still allow you to choose between building all the parts into one drawing, or building all the parts into a SOLIDWORKS assembly.

Vtl 2.9.5 swtrans.png



Check.jpgNEW - BEND-TECH 7X IMPORT

Now VTube can import the new BEND-TECH 7x format as well as the older version 6 format.

Vts 2.9.5 bend-tech 7x import.png



Check.jpgNEW - DENGLER VDS IMPORT (XYZ Data)

VTube can now import DENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.)

Vts 2.9.5 dengler vds import.png




Check.jpgNEW - DENGLER VDS EXPORT(XYZ Data)

VTube can now export DENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.)

Vts 2.9.5 dengler vds export.png




Check.jpgNEW - MINIMUM CLAMP LENGTH

VTube has a new Minimum Clamp Length field in the Part Setup menu.

If any bender data length is shorter than the minimum clamp length, then VTube will now issue a warning in the header above the viewport.

Vts 2.9.5 minimum clamp length.png



Check.jpgNEW - ZERO-DEGREE BEND ANGLE WARNING

If any bend angle is less than 0.1 degrees, VTube will now issue a "Zero-degree bend" warning in the header above the viewport.

Vts 2.9.5 zero-degree bend.png



Other Pages