=BUILD 30 - April 6, 2017=
 +
 +
==[[image:Check.jpg|25px]] NEW: UNISCAN DUAL CYLINDER FIT Feature==
 +
 +
<table cellpadding=10 width=900>
 +
<tr valign=top>
 +
<td width=300>
 +
<b>This is a MAJOR breakthrough for predicting veracity of cylinder measurements within VTube-LASER.</b>
 +
<br><br>
 +
The UNISCAN DCF feature divdes the cylinder surface data into two groups, then calculates the cylinder data and intersection points TWICE to verify repeatability.
 +
<br><br>
 +
The Point Repeatability value is reported in the Cylinder Fit window. If this value is too high, then VTube-LASER will warn you with a yellow Cylinder Fit Data window and unique sound. This allows you to remeasure the cylinder to guarantee that the measure repeats.
 +
<td>
 +
</td>
 +
<td>
 +
[[image:vtube-laser_v2.8_cylinderfit_window.png|300px]]
 +
</tr>
 +
</table>
 +
<br><br>
 +
 +
 +
  
 
=BUILD 20 - March 14, 2017=
 
=BUILD 20 - March 14, 2017=

Revision as of 04:43, 7 April 2017

Vtube-laser logo 1.96.png


Revision 2.8

Release Date: Not Released Yet


Vtube-laser v2.7 screenshot.png

Contents


BUILD 30 - April 6, 2017

Check.jpg NEW: UNISCAN DUAL CYLINDER FIT Feature

This is a MAJOR breakthrough for predicting veracity of cylinder measurements within VTube-LASER.

The UNISCAN DCF feature divdes the cylinder surface data into two groups, then calculates the cylinder data and intersection points TWICE to verify repeatability.

The Point Repeatability value is reported in the Cylinder Fit window. If this value is too high, then VTube-LASER will warn you with a yellow Cylinder Fit Data window and unique sound. This allows you to remeasure the cylinder to guarantee that the measure repeats.

Vtube-laser v2.8 cylinderfit window.png





BUILD 20 - March 14, 2017

Check.jpg NEW: MantisHub Web Server Bug Tracking

This version of VTube will allow you to choose to report software errors directly to our account at MantisHub.

This service will allow us to track bug issues with VTube-STEP and VTube-LASER.

MantisHubLogo.png



BUILD 11 - February 15, 2017

Check.jpg NEW: "Default Tolerance Ends" Value

The Default Tolerance Ends value is in the Inspection Data menu.

It allows you to set the end length default values separately from the tangent point / midpoint tolerance values.

Vtl-v2.8 Default End Tolerance.png




Check.jpg NEW: REPORT COMMANDS - Tangent Deviation AVERAGE and MAXIMUM Values

Two new array values are available for reports: AVERAGE deviation and MAXIMUM deviation.

The new commands are

  • array_dev_tmt_average
  • array_dev_tmt_maximum



See the example result in the report on the right, and the report template source to create this table shown below.

Vtl-2.8 inspection data tangent average and maximum html sample.png




Vtl-2.8 inspection data tangent average and maximum.png



BUILD 19 - February 22, 2017

Check.jpg ENHANCED: Winton WMC Communications Improvement

The process for corrections to Winton WMC files were clarified with dialogs that make it very clear what VTube-LASER Bender Setup is doing during the Winton WMC correction process.

Winton bender.png

1 - NEW HELP DIALOGS

Steps 2 and 5 are new. They carefully explain what is happening during the correction process.

2 - NEW BACKUP CREATED

Step 5 also explains that a BACKUP file is created during the process. This allows operators to always recover to the previous data if something goes wrong in the correction process. (The creation of a backup file is new in this version.)

Immediately after the user presses the Auto Correction button, this dialog appears (see step 2 below):

Vtl v2.8 winton correction existing dialog.png

Immediately after the user presses the Exit and Save setup data button, this dialog appears (see step 4 below):

Vtl v2.8 winton correction overwrite backup dialog.png




New Process Flow for Winton WMC Correction

This image shows the overall process for correction of Winton WMC files.

Vtl v2.8 winton correction process.png



Check.jpg UPDATED: Japanese Translation for User Interface

The Japanese translation of the UI was updated from version 2.6.

The new Cut Plane control (with the Diameter Cut Plane features) and the new Shortcut Key window is now translated into Japanese.

Vtl-2.8 japanese diameter cut plane.png