Difference between revisions of "VTube-LASER v1.76.3"

From ATTWiki
Jump to: navigation, search
(25px NEW: Automatic Damping for Correction)
(25px Enhanced: Reverse Calc Moves Second Leg Up)
 
(11 intermediate revisions by one user not shown)
Line 17: Line 17:
  
 
===[[image:Check.jpg|25px]] NEW:  Automatic Damping for Correction===
 
===[[image:Check.jpg|25px]] NEW:  Automatic Damping for Correction===
 +
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
VTube-LASER can now automatically damp correction data in order to avoid oversteer.<br><br>
+
VTube-LASER can now automatically damp correction data in order to avoid oversteer.
 
+
 
<br><br>
 
<br><br>
 +
 
Two adjacent 90 degree bends that are close to each other followed by a long straight causes VTube (and other measuring solutions) to overcorrect the end of the long straight.  The end is supposed be corrected to the middle straight (the MASTER) like this:
 
Two adjacent 90 degree bends that are close to each other followed by a long straight causes VTube (and other measuring solutions) to overcorrect the end of the long straight.  The end is supposed be corrected to the middle straight (the MASTER) like this:
  
 
[[image:vtube-automatic_proper_correction_tube_swing.jpg|300px]]
 
[[image:vtube-automatic_proper_correction_tube_swing.jpg|300px]]
  
But what it does is a wag-the-tail oscillation in the correction loop like this:
+
But what this tube configuration does often is a wag-the-tail oscillation in the correction loop like this:
  
 
[[image:vtube-automatic_proper_correction_tube_swing_too_much.jpg|300px]]
 
[[image:vtube-automatic_proper_correction_tube_swing_too_much.jpg|300px]]
  
The result is the correction causes the leg to overshoot the target.   This has been a traditional problem in the industry for decades.  However, I never was able to associate it with a tube shape like above until now.
+
The result is the correction causes the leg to overshoot the target.
 
+
I decided to learn from the operators what they do when this occurs.  If they have control of the loop, they work hard to damp the correction data.  Older measuring centers don’t allow for this.  But VTube-LASER does.  The only problem is that manual damping is impractical on the shop floor.
+
 
+
So I added two kinds of automatic damping.  The first one reduces the correction by 50% in any of three sets of bender axis data (the Length, Rotation, and Bend).  It allows for this damping in each axis independently – so they can choose the appropriate axis to damp.  The second kind of damping is based on the previous adjustment values.  Using the previous value causes the correction to be reduced even faster if this kind of oscillation exists.
+
 
+
The new Automatic Correction Damping as shown in the window below  (see the area with the green curve).  Without damping, for example, the first bend angle will be corrected 2.1 degrees to 98.3.  But with damping – it is corrected 1.1 degrees to 97.3 (half the correction).  (The values are rounded on the screen.)
+
  
 +
So now VTube has two kinds of automatic damping.  The first one reduces the correction by 50% in any of three sets of bender axis data (the Length, Rotation, and Bend).  It allows for this damping in each axis independently – so they can choose the appropriate axis to damp.  The second kind of damping is based on the previous adjustment values.  Using the previous value causes the correction to be reduced even faster if this kind of oscillation exists.
  
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
 
[[image:vtube-autocorrectiondamping_green_curve.jpg|400px]]
 
[[image:vtube-autocorrectiondamping_green_curve.jpg|400px]]
 +
</td>
 +
</tr>
 +
</table>
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
So now VTube has two kinds of automatic damping.  The first one reduces the correction by 50% in any of three sets of bender axis data (the Length, Rotation, and Bend).  It allows for this damping in each axis independently – so they can choose the appropriate axis to damp.  The second kind of damping is based on the previous adjustment values.  Using the previous value causes the correction to be reduced even faster if this kind of oscillation exists.
 +
</td>
 +
<td width=300>
 +
[[image:vtube-autocorrectdamping_pulldownbox.jpg|300px]]
 
</td>
 
</td>
 
</tr>  
 
</tr>  
Line 58: Line 64:
 
</table>
 
</table>
  
[[image:vtube-pro_1_76.3.jpg|600px]]
+
[[image:vtube-pro_1_76.3_BendSetup_Screen.jpg|600px]]
 +
 
 +
 
 +
===[[image:Check.jpg|25px]] Enhanced:  Reverse Calc Moves Second Leg Up in XY plane===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
VTube-LASER, VTube-PRO, and VTube-STEP now move the second leg of the first bend up when reverse-calc (LRA to XYZ) occurs.  This makes VTube operate like the legacy Bender to XYZ calculator.<br><br>
 +
</td>
 +
<td width=300>
 +
[[image:vtube-pro_1_76.3_TwoBend_White_Leg_Up.jpg|300px]]
 +
</td>
 +
</tr>
 +
</table>
  
 
=Other Pages=
 
=Other Pages=
 
*Back to [[VTube-LASER]]
 
*Back to [[VTube-LASER]]

Latest revision as of 01:04, 4 April 2012

Vtube-laser logo.jpg

Revision 1.76.3

Back to VTube-LASER
Back to VTube-PRO

Vtube-pro 1 76.3.jpg


Check.jpg NEW: Automatic Damping for Correction

VTube-LASER can now automatically damp correction data in order to avoid oversteer.

Two adjacent 90 degree bends that are close to each other followed by a long straight causes VTube (and other measuring solutions) to overcorrect the end of the long straight. The end is supposed be corrected to the middle straight (the MASTER) like this:

Vtube-automatic proper correction tube swing.jpg

But what this tube configuration does often is a wag-the-tail oscillation in the correction loop like this:

Vtube-automatic proper correction tube swing too much.jpg

The result is the correction causes the leg to overshoot the target.

So now VTube has two kinds of automatic damping. The first one reduces the correction by 50% in any of three sets of bender axis data (the Length, Rotation, and Bend). It allows for this damping in each axis independently – so they can choose the appropriate axis to damp. The second kind of damping is based on the previous adjustment values. Using the previous value causes the correction to be reduced even faster if this kind of oscillation exists.

Vtube-autocorrectiondamping green curve.jpg

So now VTube has two kinds of automatic damping. The first one reduces the correction by 50% in any of three sets of bender axis data (the Length, Rotation, and Bend). It allows for this damping in each axis independently – so they can choose the appropriate axis to damp. The second kind of damping is based on the previous adjustment values. Using the previous value causes the correction to be reduced even faster if this kind of oscillation exists.

Vtube-autocorrectdamping pulldownbox.jpg

Check.jpg Enhanced: Bender Setup Window Redesigned

VTube-LASER's Bender Setup menu was redesigned to fit more options into the window.

Vtube-pro 1 76.3 BendSetup Screen.jpg


Check.jpg Enhanced: Reverse Calc Moves Second Leg Up in XY plane

VTube-LASER, VTube-PRO, and VTube-STEP now move the second leg of the first bend up when reverse-calc (LRA to XYZ) occurs. This makes VTube operate like the legacy Bender to XYZ calculator.

Vtube-pro 1 76.3 TwoBend White Leg Up.jpg

Other Pages