Difference between revisions of "VTube-LASER v1.70"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED: Inspection Mathematics)
(25px ENHANCED: Inspection Mathematics)
 
(10 intermediate revisions by one user not shown)
Line 22: Line 22:
 
The inspection mathematics is more accurate and is now better able to work with the short straights in split bends (where VTube combines the bends to make a single large bend).
 
The inspection mathematics is more accurate and is now better able to work with the short straights in split bends (where VTube combines the bends to make a single large bend).
 
<br><br>
 
<br><br>
</td>
 
<td width=300>
 
 
 
</td>
 
</td>
 
</tr>  
 
</tr>  
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] ENHANCED: Arm Values Can Be Added to Reports===
+
===[[image:Check.jpg|25px]] REPAIR: Inspection Report Angles===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
Many report value fields were added to the report logic.  These fields can show the arm and probe calibration and accuracy values.  Add these to any report or use them to create a custom report.
+
The end angles in the inspection report are repaired and show accurate values.
<br><br>
+
[[image:vtube-laser_report_values_169.jpg|400px]]
+
<br><br>
+
This allows the current state of the arm to be printed with the report - proving that the arm was calibrated during measurement.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 43: Line 36:
 
</tr>  
 
</tr>  
 
</table>
 
</table>
 
===[[image:Check.jpg|25px]] NEW: Cut Plane Question Reminds Users To Consider Cut Plane===
 
[[image:vtube-laser_cutplane_question.jpg|350px]]
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
VTube now asks if you intend to establish a cut plane immediately after the arm is connected to VTube-LASER.
 
<br><br>
 
</td>
 
<td width=300>
 
</td>
 
</tr>
 
</table>
 
 
===[[image:Check.jpg|25px]] NEW: VTube-LASER Programmer License Mode===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
This new mode allows customers to purchase a license of VTube-LASER for programming VTube-LASER projects remotely where there is no need to connect to the FARO arm.
 
<br><br>
 
The license price for Programmer mode is significantly less expensive.
 
</td>
 
<td width=300>
 
</td>
 
</tr>
 
</table>
 
[[image:vtube-laser_programmer_mode.jpg|300px]]
 
<br><br>
 
  
 
===[[image:Check.jpg|25px]] Other Changes===
 
===[[image:Check.jpg|25px]] Other Changes===
Line 77: Line 42:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* Transfluid fails to load the diameter and radius values if the values use more than two places of accuracy beyond the decimal.  So now VTube is careful to use only two places of accuracy beyond the decimal for those two values.
+
* An "Inspection Points" label is added above the tangent point/midpoint deviation grid.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
 
</td>
 
</td>
 
</tr>
 
</tr>
 
<tr valign=top>
 
<td width=300>
 
* VTube can now correctly import a Transfluid file as MASTER data.
 
</td>
 
<td width=300>
 
</td>
 
</tr>
 
 
<tr valign=top>
 
<td width=300>
 
* The arm as mouse speed is now controlled in the FARO hardware configuration menu - not in VTube-LASER System Options as in previous versions.
 
</td>
 
<td width=300>
 
</td>
 
</tr>
 
 
 
 
</table>
 
</table>
 
<br><br>
 
  
 
===[[image:Check.jpg|25px]] Issues with this version fixed in newer versions===
 
===[[image:Check.jpg|25px]] Issues with this version fixed in newer versions===

Latest revision as of 23:51, 20 September 2011

Vtube-laser logo.jpg

Revision 1.70

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser 1 70.jpg

Contents


Check.jpg ENHANCED: Inspection Mathematics

The inspection mathematics is more accurate and is now better able to work with the short straights in split bends (where VTube combines the bends to make a single large bend).

Check.jpg REPAIR: Inspection Report Angles

The end angles in the inspection report are repaired and show accurate values.

Check.jpg Other Changes

  • An "Inspection Points" label is added above the tangent point/midpoint deviation grid.

Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg