Difference between revisions of "VTube-LASER Cylinder Fit Tolerances"

From ATTWiki
Jump to: navigation, search
(Cylinder Fit Tolerances)
(Cylinder Fit Tolerances)
Line 72: Line 72:
 
</td>
 
</td>
 
<td width=500>
 
<td width=500>
[[image:vtube-laser_default_CylinderFitTolerances.png|400px|right]]
+
[[image:vtube-laser_default_CylinderFitTolerances.png|500px|right]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 17:09, 20 February 2017


Vtube-laser logo 1.96.png


Vtube-laser 1.89 mainscreen.png



Cylinder Surface Points Calculate Cylinder Centerlines

VTube-LASER uses surface points scanned with laser or measured with ball probes to calculate tube centerlines. Regular tube scans assume that the primitive shape to solve for is a cylinder.

When solving for a cylinder centerline, it's important to report the estimated accuracy of the calculation. The estimated accuracy helps us know how confident we can be in the calculation.

Vtube-laser cylinder surfacepoints.png

Cylinder Fit Data Window Reports Estimated Maximum Fit Deviations

VTube-LASER reports the accuracy of the centerline fit in the Cylinder Fit Data window. The values are deviations for...

  • RADIUS: Estimate the maximum deviation of half the diameter.

  • X or Y POSITION: Estimate the deviation of the X or Y positions of the end points of the cylinder.

These estimate values are calculated using statistical math. The values are standard deviation x 2, which means that we have 95% assurance that the these values are the maximum deviation.

Vtube-laser cylinderfitwindow.jpg

Wobble Deviation

To simplify terminology, we say that the highest of the X and Y values is the "wobble deviation". If the centerline calculation is very good, then wobble deviation decreases. If the calculation or fit is poor, then the wobble deviation is too high.

VTube-LASER uses the wobble deviation to determine if it should ask you to remeasure the cylinder.

Vtube-laser wobbledeviation.png

Cylinder Fit Tolerances

To allow VTube-LASER to warn for poor cylinder measurements, it stores tolerances for the allowed deviations during cylinder fit. These values are setup in the Measure 1 tab of the System Options menu.

The default values are shown in the screen image on the right.

Vtube-laser default CylinderFitTolerances.png

Testing Sounds For Your VTube Computer

Not all computers play these sound files the same way. For example some computer speakers go into an idle shutdown mode that can never start up fast enough to play the short sounds.

Before changing the sounds configuration, you can double click on any sound file, and Windows should play it for you. If you hear the sound when you double-click on it, then you should be able to use it in VTube-LASER for feedback.

Sound.png

Other Pages