Difference between revisions of "Setup CNC Bender to Switch Pressure to LOW Automatically"

From ATTWiki
Jump to: navigation, search
(Constant Run Processlist)
(Constant Run Processlist Example)
Line 7: Line 7:
 
The Constant Run Processlist is good for tasks that should run ever 3/4 of a second.  The process is reserved for non-motion type commands.
 
The Constant Run Processlist is good for tasks that should run ever 3/4 of a second.  The process is reserved for non-motion type commands.
  
This is an example of watching for the high pressure output, and time beyond the last cycle:
+
This IF block of code was extracted from the "ConstantRun.cncprocesslist" file in the c:\cnc\config\ folder.
  
 
<pre>
 
<pre>
Line 23: Line 23:
  
 
The "and" keyword in the [if] statement means that ALL of these conditions in the parameter line must be true.  If they are true, then the LowPressureOn command is called.
 
The "and" keyword in the [if] statement means that ALL of these conditions in the parameter line must be true.  If they are true, then the LowPressureOn command is called.
 +
 +
==EDITING the Code==
 +
 +
Load the ConstantRun processlist into a text editor (like [[Notepad++]]), then modify the values in the code, then save the changes to the file.
  
 
==Other Pages==
 
==Other Pages==

Revision as of 22:56, 31 August 2010

Cncbender logo.jpg

This is the most efficient way to allow CNC Bender to automatically switch to LOW PRESSURE AUTOMATICALLY after some time of inactivity.

Constant Run Processlist Example

The Constant Run Processlist is good for tasks that should run ever 3/4 of a second. The process is reserved for non-motion type commands.

This IF block of code was extracted from the "ConstantRun.cncprocesslist" file in the c:\cnc\config\ folder.

[if] and, BeyondPowerOnTime=2000, BeyondLastCycleTime=5000, BeyondLastCycleTime=not(6000), output=Output_High_Pressure
  [display]AUTOMATIC HIGH to LOW PRESSURE After 5 Seconds 
  LowPressureOn
[end]

In the example above, the LowPressureOn command will run...

  • When master motor power has been on for at least 2 seconds
  • The high pressure output is ON.
  • And the processor has been idle for between 5 and 6 seconds.

The "and" keyword in the [if] statement means that ALL of these conditions in the parameter line must be true. If they are true, then the LowPressureOn command is called.

EDITING the Code

Load the ConstantRun processlist into a text editor (like Notepad++), then modify the values in the code, then save the changes to the file.

Other Pages