Difference between revisions of "How to Setup Reports to Show Bender Plus Adjusted Data"

From ATTWiki
Jump to: navigation, search
 
(STEP 2 - Enter the Bender Data Setup Menu)
Line 33: Line 33:
 
In this example, the tube has been inspected, the but the blue columns are still set to zero.  The blue columns contain the values that the bender will have before correction.  So if the blue columns are all zeros, then the reports will show bender data setup as all zeros + adjustments.<br><br>
 
In this example, the tube has been inspected, the but the blue columns are still set to zero.  The blue columns contain the values that the bender will have before correction.  So if the blue columns are all zeros, then the reports will show bender data setup as all zeros + adjustments.<br><br>
 
[[image:vtube_benderdatasetup_bluecol_zeros.jpg|500px]]
 
[[image:vtube_benderdatasetup_bluecol_zeros.jpg|500px]]
 +
</td>
 +
<td width=300>
 +
</td>
 +
</tr>
 +
</table>
 +
 +
<br><br>
 +
 +
 +
===STEP 3 - COPY Master LRA to Setup LRA===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=500>
 +
Fill the blue columns with data either from the MASTER (initial setup), or the actual data used in the bender.<br><br>
 +
To enter actual data from the bender, either press the RECALL LRA from BENDER if your bender has a connection, or printout and enter the data in the blue columns manually.<br><br>
 +
[[image:vtube_benderdatasetup_bluecol_nonzeros.jpg|500px]]
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Revision as of 03:28, 22 September 2012

Vtube-laser logo.jpg Setup VTube-LASER Reports to Show Bender Plus Adjusted Data

Vtube-laser 1 73.jpg


STEP 1 - Measure and Align the Measured Tube with the Master

Enter the MASTER data, then measure and align the measured tube to the master data.

Vtube 3mm inspection.jpg

STEP 2 - Enter the Bender Data Setup Menu

This is an important step that for building good adjustment reports. Remember that VTube gets the bender setup data in the reports from the blue columns in the Bender Data Setup menu - not the MASTER LRA data.

In this example, the tube has been inspected, the but the blue columns are still set to zero. The blue columns contain the values that the bender will have before correction. So if the blue columns are all zeros, then the reports will show bender data setup as all zeros + adjustments.

Vtube benderdatasetup bluecol zeros.jpg




STEP 3 - COPY Master LRA to Setup LRA

Fill the blue columns with data either from the MASTER (initial setup), or the actual data used in the bender.

To enter actual data from the bender, either press the RECALL LRA from BENDER if your bender has a connection, or printout and enter the data in the blue columns manually.

Vtube benderdatasetup bluecol nonzeros.jpg