Difference between revisions of "How to Setup Reports to Show Bender Plus Adjusted Data"
From ATTWiki
(→Example Report with INCORRECT Data) |
(→Example Report with Incorrectly Setup Data) |
||
Line 102: | Line 102: | ||
[[image:vtube_report_withbenderata_allzeros.jpg|600px]]<br><br> | [[image:vtube_report_withbenderata_allzeros.jpg|600px]]<br><br> | ||
− | This chart looks like an adjustment chart - but it is NOT just adjustments. It is also the current bender data plus adjustments. | + | * This chart looks like an adjustment chart - but it is NOT just adjustments. It is also the current bender data plus adjustments. |
+ | * VTube uses a rule that will not allow a length or bend angle to be negative. | ||
+ | * So it believes incorrectly that lengths 2, 3, and 7 will become negative if adjustment is applied - so VTube substitutes zeros in place of the negative values. | ||
− | |||
</td> | </td> | ||
<td width=300> | <td width=300> |
Revision as of 04:20, 22 September 2012
Setup VTube-LASER Reports to Show Bender Plus Adjusted Data
|
Contents |
When building reports with bender data plus adjustment data, it is important to remember that the report builder gets the bender data from the Bender Data Setup menu. It is critical to entering the Bender Data Setup menu to be sure that the blue column values match the current bender setup BEFORE BUILDING REPORTS.
|
STEP 1 - Measure and Align
Enter the MASTER data, then measure and align the measured tube to the master data. |
STEP 2 - Enter the Bender Data Setup Menu
STEP 3 - Establish Current Bender Values in the Blue Columns
Fill the blue columns with data either from the MASTER (initial setup), or the actual data used in the bender.
|
STEP 4 - Exit the Bender Data Setup Menu to Display Reports
Example Report with Incorrectly Setup Data
Other Pages
- Back to VTube-LASER