Difference between revisions of "How to Setup Reports to Show Bender Plus Adjusted Data"
From ATTWiki
(→Example Report with INCORRECT Data) |
(→Example Report with INCORRECT Data) |
||
Line 94: | Line 94: | ||
[[image:vtube_report_withbenderata_allzeros.jpg|600px]]<br><br> | [[image:vtube_report_withbenderata_allzeros.jpg|600px]]<br><br> | ||
− | + | This chart looks like an adjustment chart - but it is NOT just adjustments. It is also the current bender data plus adjustments. VTube will not allow a length or bend angle to enter the negative region. It believes that lengths, 2, 3, and 7 will enter the negative region if corrected, so it stops at zero.<br><br> | |
The fact that this is not correct can be confirmed with the the chart in STEP 4. The data is adjusted slightly negative - but result is still positive, so the original blue column value is adjusted. | The fact that this is not correct can be confirmed with the the chart in STEP 4. The data is adjusted slightly negative - but result is still positive, so the original blue column value is adjusted. |
Revision as of 04:09, 22 September 2012
Setup VTube-LASER Reports to Show Bender Plus Adjusted Data
|
When building reports with bender data plus adjustment data, it is important to remember that the report builder gets the bender data from the Bender Data Setup menu. Entering the Bender Data Setup menu to be sure that the blue column values matches the current bender setup BEFORE BUILDING REPORTS is critical.
Here is how to use this principle:
STEP 1 - Measure and Align the Measured Tube with the Master
Enter the MASTER data, then measure and align the measured tube to the master data. |
STEP 2 - Enter the Bender Data Setup Menu
STEP 3 - Establish Current Bender Values in the Blue Columns
Fill the blue columns with data either from the MASTER (initial setup), or the actual data used in the bender.
|
STEP 4 - Exit the Bender Data Setup Menu to Display Reports
Example Report with INCORRECT Data
Other Pages
- Back to VTube-LASER