Setup VTube-LASER Reports to Show Bender Plus Adjusted Data
|
When building reports with bender data plus adjustment data, it is important to remember that the report builder gets the bender data from the Bender Data Setup menu. Entering the Bender Data Setup menu to be sure that the blue column values matches the current bender setup BEFORE BUILDING REPORTS is critical.
Here is how to use this principle:
STEP 1 - Measure and Align the Measured Tube with the Master
Enter the MASTER data, then measure and align the measured tube to the master data. |
STEP 2 - Enter the Bender Data Setup Menu
STEP 3 - Establish Current Bender Values in the Blue Columns
Fill the blue columns with data either from the MASTER (initial setup), or the actual data used in the bender.
|
STEP 4 - Exit the Bender Data Setup Menu to Display Reports