Difference between revisions of "How to Setup Reports to Show Bender Plus Adjusted Data"
From ATTWiki
(→Example Report with Incorrect Data) |
(→Example Report with Incorrect Data) |
||
Line 79: | Line 79: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | Examine the adjustment data for this part in the Bender Data Setup menu:<br> | + | Examine the adjustment data for this part in the Bender Data Setup menu:<br><br> |
[[image:vtube_benderdatasetup_bluelengthzero_example.jpg]] | [[image:vtube_benderdatasetup_bluelengthzero_example.jpg]] | ||
− | + | <br><br> | |
− | + | Now view how this setup is applied to the reports: | |
[[image:vtube_report_withbenderata_allzeros.jpg|600px]]<br><br> | [[image:vtube_report_withbenderata_allzeros.jpg|600px]]<br><br> | ||
− | The problem with using | + | The problem with using this chart for corrections is that VTube will not allow a length or bend angle to enter the negative region. It believes that lengths, 2, 3, and 7 will enter the negative region if corrected, so it stops at zero.<br><br> |
− | + | The fact that this is not correct can be confirmed with the the chart in STEP 4. The data is adjusted slightly negative - but result is still positive, so the original blue column value is adjusted. | |
</td> | </td> |
Revision as of 03:55, 22 September 2012
Setup VTube-LASER Reports to Show Bender Plus Adjusted Data
|
STEP 1 - Measure and Align the Measured Tube with the Master
Enter the MASTER data, then measure and align the measured tube to the master data. |
STEP 2 - Enter the Bender Data Setup Menu
STEP 3 - Establish Current Bender Values in the Blue Columns
Fill the blue columns with data either from the MASTER (initial setup), or the actual data used in the bender.
|
STEP 4 - Exit the Bender Data Setup Menu to Display Reports
Example Report with Incorrect Data
Other Pages
- Back to VTube-LASER