Difference between revisions of "How to Setup Reports to Show Bender Plus Adjusted Data"
From ATTWiki
(→STEP 3 - Establish Current Bender Values in the Blue Columns) |
(→STEP 4 - Exit the Bender Data Setup Menu to Display Reports) |
||
Line 66: | Line 66: | ||
This is an example of a report with Bender + Adjusted that has been setup properly in the Bender Data Setup menu: | This is an example of a report with Bender + Adjusted that has been setup properly in the Bender Data Setup menu: | ||
[[image:vtube_report_withbenderata.jpg|600px]]<br><br> | [[image:vtube_report_withbenderata.jpg|600px]]<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ===Example Report with Incorrect Data=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=500> | ||
This is an example of a report with Bender + Adjusted where the BENDER data is set to all zeros in the Bender Data Setup menu: | This is an example of a report with Bender + Adjusted where the BENDER data is set to all zeros in the Bender Data Setup menu: | ||
[[image:vtube_report_withbenderata_allzeros.jpg|600px]]<br><br> | [[image:vtube_report_withbenderata_allzeros.jpg|600px]]<br><br> | ||
− | The problem with using the second chart for corrections with damping is that damping will not allow a length or bend angle to enter the negative region. If VTube finds any value at ZERO, and an adjustment takes it in to the negative region, then VTube will show ZERO for Bender data + Adjusted - which is not correct. | + | The problem with using the second chart for corrections with damping is that damping will not allow a length or bend angle to enter the negative region. If VTube finds any value at ZERO, and an adjustment takes it in to the negative region, then VTube will show ZERO for Bender data + Adjusted - which is not correct.<br><br> |
+ | |||
+ | For example, lengths 2,3,4,5, and 7 should not use an adjusted value of zero. | ||
</td> | </td> |
Revision as of 03:48, 22 September 2012
Setup VTube-LASER Reports to Show Bender Plus Adjusted Data
|
STEP 1 - Measure and Align the Measured Tube with the Master
Enter the MASTER data, then measure and align the measured tube to the master data. |
STEP 2 - Enter the Bender Data Setup Menu
STEP 3 - Establish Current Bender Values in the Blue Columns
Fill the blue columns with data either from the MASTER (initial setup), or the actual data used in the bender.
|
STEP 4 - Exit the Bender Data Setup Menu to Display Reports
Example Report with Incorrect Data
Other Pages
- Back to VTube-LASER