Difference between revisions of "FIF Translator Version 4 - September, 2007"
From ATTWiki
(→Data Included In Conversion) |
(→Data Included In Conversion) |
||
Line 86: | Line 86: | ||
<td bgcolor="#e3e4f5"> | <td bgcolor="#e3e4f5"> | ||
− | NEW VALUES CONVERTED: | + | NEW PROCESS VALUES CONVERTED: |
− | *Default Radius | + | *NEW - Default Radius (from first radius level) |
− | *End A Diameter | + | *NEW - End A Diameter |
− | *End B Diameter | + | *NEW - End B Diameter |
− | + | ||
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 115: | Line 113: | ||
<tr valign="top"> | <tr valign="top"> | ||
<td bgcolor="#abbad1" width=150> | <td bgcolor="#abbad1" width=150> | ||
− | <font size=4><b> | + | <font size=4><b>MACHINE DATA from EL Setup Data</b></font> |
----<br> | ----<br> | ||
</td> | </td> | ||
<td bgcolor="#e3e4f5"> | <td bgcolor="#e3e4f5"> | ||
− | *Ymin | + | *NEW - Ymin |
− | *Interference Zone 1 | + | *NEW - Interference Zone 1 |
− | *Interference Zone 2 | + | *NEW - Interference Zone 2 |
− | *Load Position | + | *NEW - Load Position |
− | *Load Offset | + | *NEW - Load Offset |
− | *Y Position Tolerance | + | *NEW - Y Position Tolerance |
− | *Pressure Die Open Code | + | *NEW - Pressure Die Open Code |
− | *Boost Delay | + | *NEW - Boost Delay |
</td> | </td> | ||
</tr> | </tr> | ||
Line 139: | Line 137: | ||
<td bgcolor="#e3e4f5"> | <td bgcolor="#e3e4f5"> | ||
− | *Any number of EXTENDED setup values are automatically converted | + | *NEW - Any number of EXTENDED setup values are automatically converted |
− | + | (Older benders (like Velog, EL-2000, and Premier) contain 40 extended setup values | |
− | + | Newer benders can contain more.) | |
*FIF Translator takes in up to 99 extended values for conversion. | *FIF Translator takes in up to 99 extended values for conversion. | ||
Revision as of 03:45, 14 September 2007
Contents |
Enhancements Information
- Now ALL data found in an FIF file is converted to the Supravision format.
- Distance data can be automatically converted to the other unit (Millimeters to Inches, or Inches to Millimeters).
- Improved error handling.
- This version retains both the XYZ and YBC data intact. There is no forced conversion in one direction or another between the two data types.
Data Included In Conversion
XYZ DATA |
|
YBC DATA |
|
VELOCITY DATA |
|
FUNCTION DATA |
|
SPECIAL FUNCTION DATA |
|
PROCESS DATA |
NEW PROCESS VALUES CONVERTED:
|
TOOL DATA |
Handles Up to 9 Radius Levels for:
|
MACHINE DATA from EL Setup Data |
|
NEW MACHINE DATA from EL Extended Setup Data |
(Older benders (like Velog, EL-2000, and Premier) contain 40 extended setup values Newer benders can contain more.)
|
Automatic Conversion of Units
The following values can be automatically converted to Inches or Millimeters during conversion: